Loading...
Hard 8 BBQ-LR060802Rone Engineering Client: ATA Mr Donnie Ward 2199 E Dove Rd., Ste B Southlake TX 76092 Project: Hard Eight Pit BBQ 688 Freeport Parkway Coppell, Texas Services. Perform In -Place Density Test in accordance with ASTM Standards. CONTRACTOR: ATA Test Methods: ASTM D -2922 ASTM D -3017 MID No. 1 Reddish Brown Clayey Sand w/ Sandstone TEST NO Select fill 1 13' south, 20' east from northwest corner, final Select fill 2 30' north, 48' east from southwest corner, final Select fill 3 40' west, 30' south from northeast corner, final Select fill 4 38' north, 50' west from southeast corner, final Technician: Jeremy Watts Report Distribution: (1) ATA Description TEST LOCATION PROJECT DATA Gauge: Troxler 3430 Gauge Serial No: 35519 Test Mode: DT MOISTURE DENSITY RELATIONS Maximum Moisture Density pcf FIF DENSITY TESTS Started: 3 IN -PLACE DENSITY TESTING Standard Counts Moisture Density Current: 624 Previous: 659 Test results on this report meet project specification. 8908 Ambassador Row, Dallas, TX 75247 4221 Freidrich Lane, Ste 195, Austin, TX 78744 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 Report No.: Project No.: Date of Service: Report Date: 262171 0611994 07/26/2006 08/02/2006 Current: 2588 Previous: 2568 Project Requirements Moisture Density 10.5 120 0 -2/ +3 95 min PROBE M/D MOISTURE WET DENSITY DRY DENSITY DEPTH No. (pcf) (pct) 6" 1 13.5 131.2 6" 1 12 9 129.3 6" 1 9.2 128 9 6" 1 10 5 131 7 Finished. 5 OOpm 115 6 114.5 118 0 119.2 L'im'it' Michael Cox, SET Project Manager DENSITY max) 96 95 98 99 LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 1 Rane Engineering Client: ATA Mr Donnie Ward 2199 E Dove Rd., Ste B Southlake TX 76092 Project: Services: CONTRACTOR: ATA Test Methods: ASTM D -2922 ASTM D -3017 MID No. 1 TEST NO Hard Eight Pit BBQ 688 Freeport Parkway Coppell, Texas Perform In -Place Density Test in accordance with ASTM Standards. Description Dark Brown Sandy Clay TEST LOCATION Building pad 1 9' north, 20' east from southwest corner, 2' below grade Building pad 2 4' south, 50' east from northwest corner, 2' below grade Building pad 3 18' north, 12' west from southeast corner, 2' below grade Building pad 4 30' north, 40' east from southwest corner Building pad 5 20' south, 38' west from northeast corner Building pad PROJECT DATA Gauge: Troxler 3430 Gauge Serial No: 35519 Test Mode: DT MOISTURE DENSITY RELATIONS Maximum Moisture Density pcf FIELD DENSITY TESTS 8908 Ambassador Row, Dallas, TX 75247 4221 Freidrich Lane, Ste 195, Austin, TX 78744 7701 W Little York, Ste 600, Houston, TX 77040 Corporate Phone: (214) 630 -9745 IN -PLACE DENSITY TESTING Current: 659 Previous: 642 Report No.: Project No.: Date of Service: Report Date: 261829 0611994 07/22/2006 08/02/2006 Standard Counts Moisture Density Current: 2586 Previous: 2572 Project Requirements Moisture Density 18 0 105 0 +1/ +4 92 -98 PROBE M/D MOISTURE WET DENSITY DRY DENSITY DEPTH No. (pcf) (pcf) 6" 1 20.3 119 6 6" 1 19.5 115 6 6" 1 200 1188 6" 1 191 1158 6" 1 19.9 119 1 DENSITY max) 99 4 95 96 7 92 99 0 94 97.2 93 99.3 95 LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 1 of 2 Report No.- 261829 Project No.- 0611994 TEST PROBE M/D MOISTURE WET DENSITY DRY DENSITY DENSITY NO TEST LOCATION DEPTH No. (pci) (pcf) max) 6 17' north, 16' west from southeast corner 6" 1 21.5 119 8 98 6 94 Test results on this report meet project specification. Technician: Jeremy Watts Report Distribution. (1l ATA Client: ATA Started. 7 15am Finished: 12.30p COPY Michael Cox, SET Project Manager i.ve.c •yn •cuI n ly LIMITATIONS The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, etc) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed and shall not be reproduced except in full without the written approval of Rone Engineering Services, Ltd. 07TM Page 2 of 2