BEI Properties-LR060228Concrete Compression Test Report J~ ENGINEERING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center Report Distribution. (1) Gooper General Contractors (1) Ray Mansoory (1) City of Coppell CMJ Report No 502-5167-016 Report Date 02/28/2006 Specifications Test Data Strength 3500 psi @ 28 Days Placement Date 01/25/2006 Slump 3 in min 5 in max Sampled By Daniel Bohon Air Content 3 % min 6 % max Weather Clear/Light Wind Concrete Temperature 55° F min 90° F max Supplier/Mix Beall/102 Ambient Temperature n/a Air Content Method ASTM C231 -Field Data Set #01 Ticket Number 13657163 Time Batched. 11 17 Time Sampled 11 50 Slump 6 in" Air Content: 3 4 % Unit Weight: N/A Concrete Temperature 71 ° F Ambient Temperature. 62° F Yardage (c.y) 20 of 90 Placement Location: Paving, Entire Parking Lot & Fire Lane, Including Entry Sample Location 24' W & 20' N of Sta 0+64 11 An asterisk (`) appears next to field data which does NOT meet specifications. Concrete Compression Test Results Set # Cylinder # Test Date Age (days) Max Load (Ibs. force) Area (sq in.} Stren th (ps~ Fracture Type 01 BRC01250601 02/01/2006 7 160360 28.27 5670 E-columnar 01 BRC01250602 02/22/2006 28 193480 28.27 6840 E-columnar 01 BRC01250603 02/22/2006 28 192240 28.27 6800 E-columnar 01 BRC01250604 Hold 28 day average 6820 Normal cylinder size. 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards. C31, C39, C138, C143, 0172, C1064, and C617 or C1231 "~ Non-Compliant: Contractor Notified 5 Gallons of Water Added On-Site, approved by~ Gus w/Cooper Construction CMJ Engineering, Inc LIMITATIONS The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 Page 1 of 1 Concrete Compression Test Report ~L • 1 ENGINEERING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax. (817) 589-9993 Client: Cooper General Contractors Project: Bloom Retail Center CMJ Report No 502-5167-017 Report Date 02/28/2006 Report Distribution (1) Cooper General Contractors (1) Ray Mansoory (1) City of Coppell _ Specifications -- ___ - Test Data Strength 3000 psi @ 28 Days Placement Date 01/25/2006 Slump 3 in min 5 in max Sampled By Daniel Bohon Air Content 3 % min 6 % max Weather Clear/Light Wind Concrete Temperature 55° F min 90° F max Supplier/Mix Beall/102 Ambient Temperature n!a Air Content Method ASTM C231 Field Data Set #02 Ticket Number 13657192 Time Batched 02:00 Time Sampled 02:20 Slump 4 in Air Content: 3 9 % Unit Weight: N/A Concrete Temperature 72° F Ambient Temperature 75° F Yardage (c.y) 110 of 110 Placement Location Paving, City Approach Sample Location Drive Approach Concrete Compression Test Results Set # Cylinder # Test Date Age (days) Max Load (Ibs force) Area (s i ) Stren th Fracture . q n (psi Type 02 BRC01250601 02/01 /2006 7 142380 28.27 5040 E-columnar 02 BRC01250602 02/22/2006 28 184660 28.27 6530 E-columnar 02 BRC01250603 02/22/2006 28 183000 28.27 6470 E-columnar 02 BRC01250604 Hotd 28 day average 6500 Normal cylinder size 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 ~ Gallons of Water Added On-Site CMJ Engineering, !nc LIMITATIONS The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. "~ Page 1 of 1