Loading...
Gateway BP(1.6)-LR060928CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061163 0113 l~~rr~con Service Date• September 20, 2006 x901 Carpenter Fnnry, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: September 28, 2006 ProLogis ~--~'" Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter /~~ Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppeil, TX Dallas TX 75234 Project No.: 94061163 Material Information Specified Strength 3500 psi ~ 28 Days Batch Time 4 48am Plant. 27 Supplier Southern Star Truck No 1848 Ticket No 1435432 Mix I D No 9339 Field Test Data Test Slump, inches. Air Content, Concrete Temperature, °F Ambient Temperature,°F Plastic Unit Weight, pcf• Result 5 50 53 80 64 144 9 Sample Information Date Cast. September 20, 2006 Time 5.20am Sampled by' Jose A. Martinez Weather Conditions Clear Accumulative Yards 30 Placement Method Pump Sample Locations: See attached sketch for Location #1 Placement Location Pavement, S of Building Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 " =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) {sq inches) Tested {days) (Ibs) (psi) 1 1 6 00 28.27 09/27/2006 7 96,160 3,400 1 2 6 00 28.27 09/27/2006 7 91,410 3,230 Average (7 Days) 3,320 3 10/18/2006 28 4 10/18/2006 28 Services - Obtain samples of fresh concrete at the placement locations, pertorm required field tests and cast compressive strength samples `i/.e /0 G e~ The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the locations} referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 4 0+~~~o,-~~aKav CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061163 0113 Service Date, September 20, 2006 l~err~con 8901 Carpenter Frwy, Ste #1100 Dallas, Texas 75247 (214)630-1010 Client: ProLogis Attn Keith Porter 2310 LBJ Freeway Ste 200 Dallas TX 75234 Report Date: September 28, 2006 Project: Freeport Corporate Ctr Bldg 6 Freeport Pkwy & Gateway Coppell, TX Project No.: 94061163 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 5 52am Plant. 27 Supplier Southern Star Truck No 1848 Ticket No 1435440 Mix I D No 9339 Field Fest Data Test Slump, inches. Air Content, Concrete Temperature, °F Ambient Temperature,~F Plastic Unit Weight, pcf• Result 5 50 48 80 60 145.2 Sample Information Date Cast: September 20, 2006 Time 6 10am Sampled by' Jose A. Martinez Weather Conditions. Clear Accumulative Yards: 110 Placement Method Pump Sample Locations. See attached sketch for Location #2 Placement Location Pavement, S of Building Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 * =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. lD (inches) (sq. inches) Tested (days) (Ibs) (psi) 2 1 6 DO 28.27 09/27/2006 7 100,080 3,540 2 2 6 00 28.27 09/27/2006 7 97,060 3,430 Average (7 Days) 3,490 2 3 10/18/2006 28 2 4 10/18/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 4 Ol-ACSIR01-FUNe Ray CONCRETE COMPRESSIVE STRENGTH TEST R rt N mber• 94061163 0113 l~~rr~con epo u Service Date• Se tember 20, 2006 8so1 carpenter Frwy, ste#1oo P Dallas, Texas 75247 {214) 630-1010 Client: Report Date: September 28, 2006 ProLogis Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Project No.: 94061163 Material Information Specified Strength 3500 psi cLD 28 Days Batch Time 6 46am Plant. 27 Supplier Southern Star Truck No 1848 Ticket No 1435448 Mix I D No 9339 Sample Information Date Cast: September 20, 2006 Time 7 48am Sampled by' Jose A. Martinez Weather Conditions. Clear Accumulative Yards. 220 Placement Method Pump Sample Locations. See attached sketch for Location #3 Placement Location Pavement, S of Building Field Test Data Test Result Specification Test Method Slump, inches: 5 00 3-5 ASTM C143 Air Content, % 4 9 3-6 ASTM C231 Concrete Temperature, aF 82 ASTM C1064 Ambient Temperature,aF 58 ASTM C1064 Plastic Unit Weight, pcf~ 145 0 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq. inches) Tested (days) (Ibs) (psi) 3 1 6 00 28.27 09/27/2006 7 99,360 3,510 3 2 6 00 28.27 09/27/2006 7 107,990 3,820 Average (7 Days) 3,670 3 3 10/18/2006 28 3 4 10/18/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were pertormed in general accordance with applicable ASTM, AA5HT0, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 4 01-ACSlR01-FWe Kay CONCRETE COMPRESSIVE STRENGTH TEST l~~rracon b 94061163 0113 Report Num er Service Date Se tember 20, 2006 8901 Carpenter Frwy, Ste #100 p Dallas, Texas 75247 (214) 630-1010 Client: Report Date: September 28, 2006 ProLogis Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Project No.: 94061163 Material Information Specified Strength 3500 psi cLD 28 Days Batch Time 9.26am Plant. 27 Supplier Southern Star Truck No 2 Ticket No 1451745 Mix I D No 9339 Sample Information Date Cast: September 20, 2006 Time 10~11am Sampled by' Jose A. Martinez Weather Conditions Clear Accumulative Yards. 320 Placement Method Pump Sample Locations. See attached sketch for Location #4 Placement Location Pavement, S of Building Field Test Data Test Result Specification Test Method Slump, inches. 6 50 3-5 ASTM C143 Air Content, % 5 4 3-6 ASTM C231 Concrete Temperature, of 80 ASTM C1064 Ambient Temperature,~F 80 ASTM C1064 Plastic Unit Weight, pcf~ 143 4 ASTM C138 * =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches (sq. inches} Tested (days) (Ibs) (psi} 4 1 6 00 28.27 09/27/2006 7 110,740 3,920 4 2 6 00 28.27 09/27/2006 7 117,980 4,170 Average (7 Days) 4,050 4 3 10/18/2006 28 4 4 10/18/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples Terracon Rep Jose A. Martinez Report Distribution (1) ProLogis (1) Meinhardt 8 Assoc Architects PLLC (1) City of Coppell TX (1) Jordan Construction Services Reviewed by' (1) City of Coppell TX (1) Meinhardt ~ Assoc Architects PLLC Robert D Ray, .T (1) Haynes Whaley Assoc Inc Senior Project ger The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 4 0,."`~°~_`'A"° "°" - - _...._ _ _. - - ~o~ ,..._..__._.. .. _-_----, --y~~;~--_' - ~ ;ems-------_"-~'~5~-- ~ ~~, ;ai{~s~>~Y4~Pi~ ~1 ~~I#~='/ =." ~j' ~ , ~ ~ ~ ~ ~ n its, --_ -____ ~siFf'~- ,A - rr ~,~~ ~' --R- F~ J ' ~. \ .,vim ~,'i1 a~T y~ _ _ - ---- ---- - -- -- -- -- - -- - -- - -- -- -- -- - --- t a i \ ~ t~9; I ~ `:~:a i~ ~ ~ A ~ i I ~ ~ ( I` ~ i 14 I } r ~ ~ l I 1 ~ ~ \ j 1 \ ~ ~ I \ } ~ a 1 \ ~ = Z nom, \ ~ ~ \~ ``,~ ~ ~yfo f-~ \} 1 \ ~ ~ 1 ~ ~ aWe ~- ~ ~ \ 1 ~ ~1 1 C O \ v ~ '~ ,-b ~'~ }\ 1} \ \`c~ _ 11'14 tli ~"1 W ~ ~ `~ \1 \ ~ '~ y ' 4 41 11 1 r ~ ~ ('dl.l) N011~3102ld 131N1 llt~~~ I `\ \~ 11 ~!' '- III '811 3S Hd \ ~ -"1' } ~\ \ ~ \ '~ \ ~. \ \ ~ ~4 \ t r „~~~ ~ ~,_ C \V ~ ~~ ~ ~`e,~~ ~r ~ ` / i i\ 1 \ -~~~ ~.\1 '!~~ 'o ~r -- - --- - ---- •~J ,.. as' may. -- -- ----------~\-\-----'c--- ~Yl~.---~id~} - ----------------- ~,~ - -----------------~~~--------~ - x ~-~ I \\ }