Gateway BP(1.6)-LR061004CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94061163 0118 11'~rr~con Service Date September 25, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date October 04, 2006 ProLogis Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste Z00 Goppell, TX Dallas TX 75234 Project No 94061163 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 2 50am Plant. 27 Supplier Southern Star Truck No 31 Ticket No 1435490 Mix I D No 9339 Water Added Onsite Before Test. 5Gallons Sample Information Date Gast. September 25, 2006 Time 3 51 am Sampled by• Jose A. Martinez Weather Conditions Clear Accumulative Yards 50 Placement Method Pump Sample Locations See attached sketch for Location #1 Placement Location Pavement, E of Building Field Test Data Test Result Specification Test Method Slump, inches 5 50 3-5 ASTM C143 Air Content, % 3 4 3-6 ASTM C231 Concrete Temperature, of 80 ASTM C1064 Ambient Temperature,~F 54 ASTM C1064 Plastic Unit Weight, pcf• 145 6 ASTM C138 * =Field Test Results do not meet project specifications Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No ID (inches) (sq inches) Tested (days) (Ibsj (psij 1 1 6 00 28 27 10/02/2006 7 86,410 3,060 1 2 6 00 28 27 10/02/2006 7 90,780 3,210 Average (7 Days) 3,140 1 3 10/23/2006 28 1 4 10/23/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 1 of 5 0, A~S~o,-FW~,a ke+. CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94061163 0118 Service Date September 25, 2006 1 ~erracon 8901 Carpenter Frvvy, Ste #100 Dallas, Texas 75247 (214)630-1010 Client: ProLogis Attn Keith Porter 2310 LBJ Freeway Ste 200 Dallas TX 75234 Report Date• October 04, 2006 Project: Freeport Corporate Ctr Bldg 6 Freeport Pkwy & Gateway Coppell, TX Project No.. 94061163 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 4 02am Plant 27 Supplier Southern Star Truck No 120 Ticket No Mix I D No 9339 Field Test Data Test Result Slump, inches 5 75 Air Content, % 3 0 Concrete Temperature, ~F 79 Ambient Temperature,oF 52 Plastic Unit Weight, pcf• 147 4 Sample Information Date Cast. September 25, 2006 Time 4 50am Sampled by Jose A. Martinez Weather Conditions Clear Accumulative Yards 120 Placement Method Pump Sample Locations See attached sketch for Location #2 Placement Location Pavement, E of Building Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 " =Field Test Results do not meet project specifications. Laborafory Test Data Set Specimen Diameter Area No ID (inches) (sq inches) 2 1 6 00 28.27 2 2 6 00 28.27 2 3 2 4 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 10/02/2006 7 78,830 2,790 10!02/2006 7 79,060 2,800 Average (7 Days) 2,800 10/23/2006 28 10/23/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 2 of 5 °,-~s~R°'-`'"°'e"ey CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94061163 0118 11'~rracon Service Date September 25, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date•October 04, 2006 ProLogis Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 5 35am Plant. 27 Supplier Southern Star Truck No 31 Ticket No 1435507 Mix I D No 9339 Water Added Onsite Before Test. 10Gallons Field Test Data Test Slump, inches Air Content, Concrete Temperature, ~F Ambient Temperature,°F Plastic Unit Weight, pcf• Result 5 50 * 34 80 53 147 0 Project No 94061163 Sample Information Date Cast September 25, 2006 Time 6 13am Sampled by• Jose A Martinez Weather Conditions Clear Accumulative Yards 220 Placement Method Pump Sample Locations See attached sketch for Location #3 Placement Location Pavement, E of Building Specification 3-5 3-6 Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 * =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No ID (inches) (sq inches) Tested (days} (Ibs) (psi) 3 1 6 00 28.27 10/02/2006 7 81,070 2,870 3 2 6 00 28 27 10/02/2006 7 86,040 3,040 Average (7 Days) 2,960 3 3 10/23/2006 28 3 4 10/23/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shalt not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 5 0, ncs~ao,-F~~~e key CONCRETE COMPRESSIVE STRENGTH TEST Report Number 94061163 0118 11'err~con Service Date• September 25, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date. October 04, 2006 ProLogis Project: Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dalias TX 75234 Project No 94061163 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 7 07am Plant 27 Supplier Southern Star Truck No 5019 Ticket No 1435518 Mix I D No 9339 Sample Information Date Cast. September 25, 2006 Time 7 33am Sampled by Jose A Martinez Weather Conditions Clear Accumulative Yards 320 Placement Method Pump Sample Locations See attached sketch for Location #4 Placement Location Pavement, E of Building Water Added Onsite After Test 5 Gallons Field Test Data Test Result Specification Test Method Slump, inches 5 00 3-5 ASTM C143 Air Content, % 3 4 3-6 ASTM C231 Concrete Temperature, of 7g ASTM C1064 Ambient Temperature,°F 56 ASTM C1064 Plastic Unit Weight, pcf~ 145 5 ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq inches) Tested (days) (Ibs) (psi) 4 1 6 00 28.27 10/02/2006 7 84,150 2,980 4 2 6 00 28.27 10/02/2006 7 83,260 2,940 Average (7 Days) 2,960 4 3 10/23/2006 28 4 4 10/23/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods, This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 4 of 5 ~,-acsrao,-F~e key CONCRETE COMPRESSIVE STRENGTH TEST Re ort Number 94061163 0118 l~erracon p 8901 Carpenter Frwy, Ste #100 Service Date• September 25, 2006 Dallas, Texas 75247 (214)630-1010 Client• Report Date.October 04, 2006 ProLogis Project Freeport Corporate Ctr Bldg 6 Attn Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Project No.: 94061163 Material Information Specified Strength 3500 psi @ 28 Days Batch Time 8 OOam Plant 27 Supplier Southern Star Truck No 5019 Ticket No 1435525 Mix I D No 9339 Field Test Data Test Result Slump, inches 6 00 Air Content, % 3 5 Concrete Temperature, °F 81 Ambient Temperature,~F 70 Plastic Unit Weight, pcf~ 146 7 Sample Information Date Cast September 25, 2006 Time 9 02am Sampled by' Jose A. Martinez Weather Conditions Clear Accumulative Yards 410 Placement Method Pump Sample Locations See attached sketch for Location #5 Placement Location Pavement, E of Building Specification Test Method 3-5 ASTM C143 3-6 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 * =Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID (inches) (sq inches) Tested (days) (Ibs) (psi) 5 1 6 00 28.27 10/02/2006 7 89,860 3,180 5 2 6 00 28.27 10/02/2006 7 91,930 3,250 Average (7 Days) 3,220 5 3 10/23/2006 28 5 4 10/23/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples Terracon Rep Jose A Martinez Report Distribution (1) ProLogis (1) Meinhardt & Assoc Architects PLLC (1) City of Coppell TX (1) Jordan Construction Services Reviewed by _ (1) City of Coppell TX (1) Meinhardt 8 Assoc Architects PLLC Robert D Ray, S.E. (1) Haynes Whaley Assoc Inc Senior Project Mal}z( The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of (#~ client indicated above and shall not be reproduced except in full without the written consent of our company Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials Page 5 of 5 °' "`yp°' `'"°" "°" t ~__~._---_~- _--°- -~- - - - - - - - - - - - -_ - - ~ ~. i~ ~~ I 1 1 ~.~*,L1, 1 {~~ ~ X11 +I I ~• Ir~ 1 ~ - ~~ i~ (_!;' ~~ a ~ ~~~;~~ ~~ ~ _ ~.:: li T1=1 'I ~.~ 4 ~ _ ~~ ~ ~ ~ I ~ ~ ~ ~ I 1 i.~ ;~ ~ \ ~ YP~r1° r ~ ~ I V ~a ~- ~ :,~ ,~,~ ~ I J t '~ I '~ er I~ .. ~ ` • i ` Y ~ I 1 I ~, I ~. • ' ~'ERRACON REPORT N0. ~ ~ ~ , ,on ,~,-t ~ III r i ;! r ~ I I y I f ~ i sL 4 ~ ~` , I 1 "~ ,~, ~ 1 .., I I I ~'` ~.y,'l' I ~ ~` °: I I ''j - I ` ~ "t, ~ u I y ~ ft .. Z' '~ ~ t I , ~I I ', I ' I __ _____~\ ~. y~_ f,~I 1 T• ~i F .Jc ~.. I; I I `O~ L i .,~ I 1i I~ _ ~ ~a is Des =0 ~ - ~~I ~ ~ :, ~~ ; \ ~ r.' ~ ~i I ~.. ~` ~ ~~ ~ I ~ -~' I ~~ _ - € I ' , , \ ~ ( ~ ~ # Y jL li ~!° ~ i i Q . ~ ~ :: r~- - J f I i ` ua ! ~...,n.~ .4 u. L i ~\t' c+ ~.~.' ~ ~ I b , r~ I 'l ~b I'. I I ~ ~ , ~~ s: t ; " I'~~' I I I ;~' ,. ; I - I ~~ I ~ ~~ ~ 1 ~,, ~~ I1 I ~ I ~Z~ I y I ~ ~~ ~ i ~/ ":~ I ;III .:. i j ! ~ \ .I /` i~ / X22 %, ~ , { I` ~' II ~ ~ - ' ~ v i` ~%' I ~I ~- ~ ~ ~~ ~ c I `,~~ ~ ~ • ~ I ' I ~ l ~~l ~ ..~; ._. :.. ...::~_. r:.~_...._,_ ..,._ .,,.. ' 1 ... _ ~.. :~ ::x.~..., . ..: .~ -_ _. - _ __ --- ,~ , , -- ~ I ___ -