WA9701-CS060531 (2)Keit M arvin - denton tap walk through irr 5 -06 doc Pa 1� r x -. c i -r r o r COPPELL PARKS & RECREATION DEPARTMENT Memorandum Date May 31, 2006 To Keith Marvin, Civil Engineer From Lloyd Mauch, Parks Operations Supervisor Re Denton Tap Irrigation and Landscape Walk Through An irrigation and landscape walk- through was performed on May 24, 2006 regarding the Water Main Construction on Denton Tap Rd. from Southwestern Blvd to Bethel Rd. Bob Jones a Parks Crew Leader, John Elias the Parks Manager and John Skinner from J T Dersner where at the walk - through. The following is a punch list of items that was generated from the walk - through and needs to be addressed before we can sign off on this project. Starting from Southwestern Blvd. by the Dairy Queen (DQ) and heading North to Bethel Rd. A total of sixteen (16) zones and two (2) controllers where involved in this walk - through. * All irrigation heads need to be 4" Rainbird 1804 Sampras Zone 7 DO controller • doesn't come on from controller • wires exposed on valve • needs new solenoid • bleed screw on valve is broke off • box lids broken & box broken • dead sod • areas not sodded • grade uneven Keith Marvin - denton tap walk through irr 5 -06 doc - Page 2 Zone 6 DO controller • doesn't come on from controller from proper zone, it comes on with zone 1 • dead sod • needs more sod Zone 5 DO controller • comes on from controller but with wrong zone • valve box is too low • wrong heads used • needs '/4 nozzle on North end cap (grass and concrete edge), not %2 nozzle • adjust nozzles, too much over spray into street • grade uneven • sod issues Zone 4 DO controller • doesn't come on from controller • mixture of heads used • valve box lids are wrong they don't match boxes • heads all need adjusting • dead sod • more sod • rough grade Zone 3 DO controller • doesn't come on from controller • no wires for valve • missing head on west side Zone Z DO controller • valve is bad • valve doesn't come on manually or from controller • need valve and quick coupler in separate boxes • more sod • dead sod • uneven grade • could not check heads due to valve not coming on Zone 1 DO controller • valve doesn't come on from controller • valve not wired properly • head layout has no pattern down the middle row • middle row heads have wrong nozzles throughout • valve boxes too low • grade issues • dead sod • more sod OA Keith Marvin - denton tap walk through irr 5 -06 doc Pa 3 * Starting at Railroad Tracks and heading North Controller located by bridge at Bethel and Denton Tap Intersection Zone 12 North of Railroad Tracks • doesn't come on from controller • remove blue pipe from valve box • middle row nozzles are halve nozzles and need to be full • heads need to be adjusted, spraying in the street • dead sod • grade issues Zone 11 North of Railroad Tracks • doesn't come on from controller • remove blue pipe from valve box • bleed screw is broken on valve • wire connections in valve box need to be visible with proper connectors • dead sod • grade issues • mixture of heads used Zone 10 North of Railroad Tracks • doesn't come on from controller • heads tilted, leaning too far back • valve box needs to be leveled Zone 9 North of Railroad Tracks • doesn't come on from controller • remove blue pipe from valve box Zone 8 North of Railroad Tracks • doesn't come on from valve • wrong wire connectors • middle row nozzles are quarter nozzles and need to be full • dead sod Zone 7 North of Railroad Tracks • doesn't come on from controller • remove blue pipe from valve box • wrong wire connectors • wrong valve box lid • dead sod 3 r eith Marvin - denton tap walk through irr 5 -06 doc Zone 6 North of Railroad Track • doesn't come on from controller • remove blue pipe from valve box • exposed wiring needs proper connectors • valve box too low • dead sod • grade is too low Zone 5 North of Railroad Tracks • doesn't come on from controller • valve not wired up • grade is too low and holes Zone 4 North of Railroad Tracks • doesn't come on from controller • remove blue pipe from valve box • wrong wire connectors • wired up wrong • sod is stressed needs water • heads are too low and leaning • heads need to be adjusted, spraying in the street • missing one (1) head on East side on median Cc John Elias, Parks Manager Cc. Rick O'Dell, Construction Inspector Page 4] 4 Keith Marvin - Denton Tap Irr & Landscape walk- through From: Lloyd Mauch To: Keith Marvin Date: 6/1/2006 8 34 00 AM Subject: Denton Tap Irr & Landscape walk- through Keith, I have attached the punch list for J T Dersner below If you have any questions please don't hesitate to contact me I am faxing John Skinner with J T Dersner a copy as well. Page 1 Lloyd Mauch City of Coppell Parks Operations Supervisor