Loading...
ST9902-LR060928 Concrete Compression Test Report eM J ENGINEERING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: City of Coppell . ~ West Sandy Lake RoaY' Reconstruction Report Distribution: (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins CMJ Report No.: 687-5192-133 Report Date: 09/28/2006 3 % min 6 % max n/a 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method Test Data 08/29/2006 Richard Jones Cloudy/Light Wind Southem Star/9618-B ASTM C231 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 3600 psi @ 28 Days 4 in max Ticket Number: Slump: Concrete Temperature: Placement Location: 1452863 Time Batched: 08:30 Time Sampled: 09:10 3 in Air Content: 3.3 % Unit Weight: n/a 87" F Ambient Temperature: 800 F Yardage (c.y.): 5 of 5 Inlet & Curb, Southbound Oak Bend at Sandy Lake, Sta. 0+43.34 Lateral C1-5 Sample Location: Same Concrete Compression Test Results Cylinder Age Max Load Area Strenijth Fracture Set # # Test Date (days) (Ibs. force) (sq.in.) (pSI Type 01 SLR08290601 09/05/2006 7 155560 28.18 5520 E-columnar 01 SLR08290602 09/26/2006 28 180240 27.99 ~40 E-columnar 01 SLR08290603 09/26/2006 28 181490 27.99 t..480 E-columnar 01 SLR08290604 Hold 28 day average 6460 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C o Gallons of Water Added On-Site **REVISED REPORT 9/12/2006** Strength specification changed from 3000 to 3600 Concrete temperature specification removed Ambient temperature specification revised to remove maximum temperature. I~' ~. ~~ n!~ CMJ Engineering, Inc R. Carl Lee, SET. Vice PresidenVCMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. o I Page 1 of 1