ST9902-LR060602
In-Place Soil Moisture/Den~ty Tests by Nuclear Method
eM J ENGINEER'NG, INC.
7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993
Client:
Project:
City of Coppell
West Sandy Lake Road
Reconstruction
Report Distribution: (1) City of Coppell
(1) City of Coppell
(1) Tiseo Paving Company
(1) Teague Nail & Perkins
CMJ Report No.: 687-5192-043
Report Date: 06/02/2006
Specifications
Percent Compaction: +95% min +100% max
Moisture Content: opt +0% to +5%
Test Data
Date Tested: OS/26/2006
Technician: Jory Goldring
Curve No.
Test Method
Material Description
Optimum Maximum Dry
Moisture % Density pcf
2207
ASTM D-698
Dark Brown Clay
22.0 99.0
In-Place Test Results
Probe Percent Wet Density Dry Density Percent
Depth Moisture (pet) (pet) Density
6" 24.3 122.6 98.6 ~6
6" 25.7 120.0 95.5 96.5
6" 24.8 121.3 97.2 98.2
Test
No
Elevation
or Lift
Location
Ref.
Curve
173.0
174.0
175.0
1 st Lift
1 st Lift
1 st Lift
Roadway Embankment- Royal Lane
450' North of South End 2207
600' North of South End 2207
750' North of South End 2207
Test results on this report meet project specification.
Test Method{s): ASTM D2922, ASTM D3017
Gauge: CPN
Gauge SN: 6660
Std. Density Count: 60012
R. Carl Lee, S.E.T.