Apostles-LR 971031ALPHA TESTING, INC. 2209 Wisconsin St. ~~~, Suite 100 Dallas, Texas 75229 (214) 620-8911 TESTED FOR: LEWISVILLE, TEXAS PROJECT: CHURCH OF THE APOSTLES COPPELL, TEXAS REPORT OF CONCRETE COMPRESSION TEST OCTOBER 31, 199? DATE OF ISSUE: OUR REPORT NO.: 97505-26 FIELD DATA PAVING: SOUTH DRIVE APPROACI-F; 5' NORTH & 5' EAST LOCATION OF CONCRETE PLACEMENT OF THE SE CORNER DATE PLACED 10 / 31 / 9 7 PLANT 1 TIME 04.00 DELIVER TICKET NO 278184 SLUMP (ASTM C-143) ~ • 5 MIX PROPORTIONS (SSD) N/A AIR CONTENT (ASTM C-231 ^ OR C-173 Id )5 • 5 CEMENT N/A AIR TEMPERATURE 6 9 WATER N/A CONCRETE TEMPERATURE 7 5 FINE AGGREGATE NIA DATE RECEIVED 11 / 01 / 9 7 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY ARMANDO ADMIXTURE N/A MIX DATA SUBMITTED BY SPECIMENS CAPPED IN ACCORD RF~DI-MIX ANCE WITH A TM C-617 OR C-1231 COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6" X 12") (ASTM C-39) LAB TYPE ~ DATE I AGE TOTAL NO. CURING TESTED DAYS LOAD 35 LAB lI/07/9 7 86,942 36 LAB 11/28/9' 28 131,967 37 i LAB 11/28/971 28 134,044, 3 8 ~ LAB i HOLD H j I :__ ___ i ~ Specifications CC'~'PUDATA-GG01083-34 Il- ~_- AREA COMPRESSIVE STRENGTH, PSI 28.27 3,070 28.27, 4,670 28.27.! 4,740 - ~_ .__~ _ _ - ~_~ ~ 0_j R ectfully Subm' d _- _l ALPH ,I PAT STETTNER REMARKS C.YCylinders made by ALPHA representative. ^ Cylinders made by Architect's or Contractor's representative. [~G~ylinders picked up by ALPHA laboratory. Cylinders delivered to ALPHA laboratory. Compressions test results comply with applicable specifications. ' Compression test results do not comply with applicable specifications. II