Apostles-LR 971007ALPHA TESTING, INC.
CSI
TESTED FOR: LEWISVILLE, TEXAS
2209 Wisconsin St.
~j~, Suite 100
Dallas, Texas 75229
(214) 620-8911
CHURCH OF THE APOSTLES
PROJECT: COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
DATE OF ISSUE:
OUR REPORT NO.:
OCTOBER 7, 1997
97505-23
FIELD DATA
PAVING: 35' WEST & 40' NORTH OF SW CORNER OF
LOCATION OF CONCRETE PLACEMENT BUILDING PAD IN FIRE LANE
DATE PLACED l O/ O 7/ 9 7 PLANT N/A
TIME 06:4 5 DELIVER TICKET NO N/A
SLUMP (ASTM C-143) ~ 4.75 MIX PROPORTIONS (SSD) N/A
AIR CONTENT (ASTM C-231 QOR C-173 ^ )5 . 5 CEMENT N/A
AIR TEMPERATURE 6 9 WATER N/A
CONCRETE TEMPERATURE $ Q FINE AGGREGATE N/A
DATE RECEIVED 1 O / O $ / 9 7 COARSE AGGREGATE N/A
FIELD DATA SUBMITTED BY J , S . ADMIXTURE N/A
MIX DATA SUBMITTED BY REDI-MIX
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 IgOR C-1231 ^
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C-39)
LAB
NO. TYPE
CURING DATE
TESTED AGE
DAYS TOTAL
LOAD AREA COMPRESSIVE
STRENGTH, PSI
27 LAB 10/14/97 7 85,092 28.27 3,010
28 LAB 11/04/97 28 28.27
29 LAB 11/04/97 28 28,27
30 LAB HOLD H
Specifications 2$ 3, 6 0 0
COMPUDATA-CG0108334
REMARKS
C~7/Cylinders made by ALPHA
representative.
^ Cylinders made by Architect's
or Contractor's representative.
~y finders picked up by ALPHA
laboratory.
^ Cylinders delivered to ALPHA
laboratory.
^ Compressions test results comply with
applicable specifications.
^ Compression test results do not comply
with applicable specifications.
Respectfully Submitted
~LPHA TESTING, iNC.
PAT STETTNER