Austin Place-CS 961011~' r ar. s' . TEXAS INDUSTRIES 1341 W. MOCKINGBIRD LANE • DALLAS, TEXAS 75247-6913 • 214/647-6700 October 11, 1996 Austin Bridge & Road 11143 Goodnight Lane Dallas, Tx 75229 Attention: Mr. Gary Atwood RE: Austin Place - Coppell 8272 8274 Gentlemen: The attached concrete mix designs utilizing the appropriate ASTM C-33 or ASTM C-330 aggregate are proposed for use on the above referenced project for ready mix concrete to be furnished by TXI. To ensure that the correct mix is delivered to your project, please order by the mix design number which appears in the upper left hand corner of the mix design. Texas Industries certifies that the above mix designs, when ordered by specified design identity, will meet or exceed the indicated design strength at the designated age when tested in accordance with the applicable and current ASTM Standards C 31, C 39, C 78, C 172, C 293, applicable provisions of C 94, and evaluated in accordance with applicable provisions of ACI Building Code. TXI would like to be included on your mailing list to receive all test reports. ASTM C 94, Section 14 entitles a manufacturer to receive copies of all tests reports when strength of concrete is used as a basis for acceptance. Please contact us if you have any questions or require additional information. Please notify TXI of approval of the proposed mix designs prior to their use. Failure to notify us prior to first placement shall constitute acceptance. To ensure that the proper mix designs are ordered please send a copy of this letter, after approval, to the above referenced project to be used by the person ordering the concrete for this job. Sincerely; TEXAS INDUSTRIES, INC. /~a~~~ Michael A. Caldarone, P.E. Manager-Q.A./Q.C. Mix #: 8272 Description: 5.OOSK ADMIX/AEA 1"CS Strength: 3000 PSI @ 28 Days SLIP FORM PAVING Maximum Coarse Aggregate: Maximum Water/Cement Ratio: Cement/Cementitious Content: Maximum Placement Slump: Air Entraining Agent: Admixture: 1" - #4 CRUSHED STONE 6.20 gal/sack or 0.549 lbs/lb 5.00 sacks (per cubic yard) 3.00 inches ASTM C-260 ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 470 lbs. TYPE I 1840 lbs. 1" - #4 CRUSHED STONE 1352 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Specified Air Content: 3.Oo - 6.0% Placement Slump: 2.00 + or - Mix #: 8274 Description: 6.OOSK ADMIX/AEA 1"CS Strength: 4000 PSI @ 28 Days HAND PLACED PAVING Maximum Coarse Aggregate: Maximum Water/Cement Ratio: Cement/Cementitious Content: Maximum Placement Slump: Air Entraining Agent: Admixture: Type A 1.00 inches 1" - #4 CRUSHED STONE 5.17 gal/sack or 0.457 lbs/lb 6.00 sacks (per cubic yard) 4.00 inches ASTM C-260 ASTM C-494 Type A or D MATERIAL QUANTITIES PER 1.0 CUBIC YARD AT S.S.D 564 lbs. TYPE I 1840 lbs. 1" - #4 CRUSHED STONE 1273 lbs. CONCRETE SAND 258 lbs. or 31.0 Gallons of Water 2.0 to 4.0 oz/cwt of ASTM C-494 Type A Specified Air Content: 3.0% - 6.Oo Placement Slump: 3.00 + or - 1.00 inches PUMPING RECOMMENDATIONS 1. 5" minimum diameter lines with no reduction to smaller lines. 2. Keep rubber hose to absolute minimum length and plan pipe with as few 90 degree angles as possible. 3. Slumps and test cylinders should be taken at discharge end of hose for strength guarantee to be valid. 4. To prime pump lines, a minimum of 8.0 sack grout should be used for lubrication. In case of strength concrete, equivalent strength grout should be used if the grout remains in the placement. 5. Pump mixes are based on minimum cement content pumped at ground level. As pump line increases in length or height and/or layout configuration changes, additional cement may be required to assure strength and pump ability at additional cost to the contractor. 6. TXI cannot control, and is therefore not responsible for excessive loss of entrained air when loss occurs due to pressure differentials created as a result of boom configuration or free fall discharge from end of hose. We are enclosing all available back data for the above referenced mix design. If the strength information is not available or is not sufficient, confirmation cylinders may have to be made by your testing laboratory. TEXAS INDIISTRIES CONCRETE DESIGN SVALIIATION Data: 10/11/96 ** Statistics Ca~mpilad From Independent Laboratory Tast Spacimeas ** Mix Number: 8272 Strength: 3000 PSI ® 28 Daya 28 Day Teat Data Temperature Test Plant (Fahrenheit) Placement Percent --------- 28 Day -------- Cumulative Moving Number Date Number Ambient Concrete Slump~(in) -------- of Air ------- PSI 1 ------- PSI 2 ------- PSI Avg ------- Average ---------- Avg of 3 -------- Range ----- ------ 1 -------- 05/30/96 ------ 50 ------- -------- 89 - 5.75 3.5k 3510 3440 3475 3475 70 2 05/31/96 50 87 5.50 4.2~ 4350 4480 4415 3945 130 3 06/03/96 50 91 6.00 3.1t 4180 4120 4150 4013 4013 60 4 06/03/96 50 89 6.25 3.8$ 4130 4030 4080 4030 4215 100 5 06/04/96 50 88 5.75 3.5$ 3960 4090 4025 4029 4085 130 6 06/04/96 41 77 85 5.00 5.8~ 4420 4220 4320 4078 4142 200 7 06/04/96 41 83 86 5.00 5.0~ 4000 4040 4020 4069 4122 40 8 06/04/96 41 85 89 5.00 4.8~ 4000 4010 4005 4061 4115 10 9 06/04/96 41 83 85 5.00 4.9~ 4050 3980 4015 4056 4013 70 10 06/04/96 41 84 68 6.50 5.8~ 3800 3720 3760 4027 3927 80 11 06/04/96 41 83 BS 6.50 5.7~ 4160 4230 4195 4042 3990 70 12 06/04/96 41 76 84 5.50 5.8~ 3990 3930 3960 4035 3972 60 13 06/04/96 41 76 66 5.50 5.6t 3980 4050 4015 4033 4057 70 14 06/04/96 41 71 81 4.50 5.4$ 4580 4630 4605 4074 4193 50 15 06/04/96 41 74 79 4.75 5.5~ 4710 4430 4570 4107 4397 280 16 06/04/96 41 71 80 5.00 5.3$ 3750 3780 3765 4086 4313 30 17 06/04/96 41 80 84 1.50 N/A 4670 4650 4660 4120 4332 20 18 06/04/96 16 78 80 3.50 N/A 5300 5360 5330 4187 4585 60 19 06/05/96 50 93 6.00 3.4~ 3600 3770 3685 4161 4558 170 20 06/06/96 50 89 6.00 4.1$ 4230 4350 4290 4167 4435 120 21 06/06/96 41 94 86 3.50 N/A 4380 4450 4415 4179 4130 70 22 06/06/96 16 84 90 4.50 N/A 4740 4880 4810 4208 4505 140 23 06/07/96 50 BS 6.25 4.4~ 3380 3420 3400 4172 4208 40 24 06/07/96 12 85 89 5.00 N/A 4070 4050 4060 4166 4090 20 25 06/10/96 50 79 6.25 4.7~ 3910 4020 3965 4160 3808 110 26 06/11/96 50 89 6.00 3.8~ 3630 3740 3685 4141 3903 110 27 06/13/96 13 92 89 7.00 N/A 3960 3950 3965 4135 3872 30 28 06/17/96 31 88 83 4.00 5.0$ 4110 4490 4300 4141 3983 380 29 06/17/96 31 85 83 4.50 S.Ok 3670 3720 3695 4125 3987 50 3D 06/17/96 13 92 95 ------- 4.50 --------- N/A ------- 4490 4400 4445 4136 4147 90 *** Averages *** ------- 82 - 86 5.20 4.7~ COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix Num: 8272 Strength: 3000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced, provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c + 1.34(SD) = 3000 + 1.34(412.4) = 3553 F'cr = F'c + 2.33(SD) - 500 = 3000 + 2.33(412.4) - 500 = 3461 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ............................ 5330 psi Minimum Value ............................ 3400 psi Range .................................... 1930 psi Average Strength ......................... 4136 psi Standard Deviation ....................... 412 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 ............... 3553 psi Design excess beyond code requirements... 583 psi TSZAS INDIISTRI83 CONCRSTB DBSIGN 8SIALIIATION Dots: 10/09/96 ** Statistics Compiled From Iadepsadeat Laboratory Teat Spacimeas ** Mix Number: 8274 Strengths 4000 PSI • 28 Daya 28 Day Test Data Temperature Test Plant (Fahrenheit) Placement Percent --------- 28 Day -------- Cumulative Moving Number Date Number Ambient Concrete Slump(in) - of Air ------- PSI 1 ------- PSI 2 ------- PSI Avg ------- Average ---------- Avg of 3 -------- Range ----- ------ 1 -------- 03/12/96 ------ 41 ------- -------- 74 -------- 6.20 5.8$ 4930 5060 4995 4995 130 2 03/13/96 25 72 76 4.00 4.2g 4580 4680 4630 4813 100 3 03/19/96 31 72 6.00 3.St 4510 4420 4465 4697 4697 90 4 03/21/96 40 69 3.70 7.Ot 5520 5270 5395 4871 4630 250 5 03/21/96 40 68 5 4.20 N/A 4460 4340 4400 4777 4753 120 6 03/22/96 41 73 4.00 4.8~ 4750 481D 4780 4778 4858 60 7 04/01/96 40 71 5.20 4.4~ 4560 4600 4590 4751 4590 20 8 04/08/96 41 75 70 1.OD 4.8$ 6110 5850 5980 4904 5117 260 9 04/10/96 40 75 4.70 5.7t 4740 4660 4700 4682 5090 80 10 04/12/96 18 69 76 3.50 5.2t 4910 5200 5055 4899 5245 290 11 04/15/96 25 52 69 5.00 N/A 4570 4590 4560 4870 4778 20 12 04/24/96 31 59 66 5.50 4.6~ 4160 4110 4135 4809 4590 50 13 04/24/96 31 54 64 5.00 4.8$ 480D 4720 4760 4805 4492 80 14 04/24/96 31 53 64 4.50 4.5~ 4390 4470 4430 4778 4442 80 15 04/25/96 41 79 70 5.00 N/A 4770 4810 4790 4779 4660 40 16 04/26/96 31 83 69 4.5D N/A 4580 4620 4600 4766 4607 40 17 04/26/96 31 67 60 5.00 N/A 4730 4920 4825 4771 4738 190 18 05/03/96 40 87 4.20 4.8~ 4640 4660 4650 4764 4692 20 19 05/06/96 41 87 2.50 3.3~ 4880 5060 4970 4775 4815 180 20 05/07/96 41 88 3.70 3.7t 4960 5190 5075 4790 4898 230 21 05/08/96 18 87 87 4.50 N/A 4780 4840 4810 4791 4952 60 22 06/12/96 38 9D 4.70 4.7~ 4890 4770 4830 4793 4905 120 23 06/14/96 40 92 4.75 3.8$ 4960 4820 489D 4797 4643 140 24 06/14/96 40 93 5.75 4.2~ 4920 9790 4855 4800 4858 130 25 06/14/96 31 92 99 5.00 N/A 6190 6300 6245 4857 5330 110 26 06/18/96 38 103 4.00 N/A 5150 5260 5205 4871 5435 110 27 06/19/96 40 93 4.75 3.53 5660 5560 5610 4898 5687 100 28 06/20/96 38 97 4.50 4.1~ 4460 4530 4495 4684 5103 70 29 06/24/96 40 90 5.00 9.9$ 4790 4670 4730 4878 4945 120 30 06/24/96 40 92 -- 4.50 --------- 4.8~ ------- 4410 4340 4375 4862 4533 70 **• Averages *** ------- 70 ------ 77 4.50 4.6~ COMMENTARY OF STATISTICAL EVALUATION OF CONCRETE DESIGN RESULTS Mix Num: 8274 Strength: 4000 psi @ 28 Days Paragraph 5.5 of ACI 318-89 provides that as data becomes available during construction, the amount by which (F'cr) must exceed the specified value of (F'c) may be reduced,~provided: (a) 30 or more test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.1, or (b) 15 to 29 test results are available and average of test results exceeds that required by Section 5.3.2.1, using a standard deviation calculated in accordance with Section 5.3.1.2. The required average compressive strength has been calculated using a standard deviation calculated in accordance with ACI 318-89 Section 5.3.1.1 or Section 5.3.1.2 and is the larger value of these calculations: F'cr = F'c + 1.34(SD) = 4000 + 1.34 (458.1) = 4614 F'cr = F'c + 2.33(SD) - 500 = 4000 + 2.33 (458.1) - 500 = 4567 SUMMARY OF STATISTICAL ANALYSIS 28 Day Test Data Number of Tests .......................... 30 Maximum Value ................... ........ 6245 psi Minimum Value ............................ 4135 psi Range .................................... 2110 psi Average Strength ......................... 4862 psi Standard Deviation .............. ........ 458 psi Required Average Strength to satisfy minimum probability conditions of ACI 318-89 Section 5.3.2.1 .... .......... 4614 psi Design excess beyond code requirements... 248 psi tXI TEXAS INDUSTRIES ~ MIDLOTHIAN CEMENT PLANT, 245 Ward Road • Midlothian, Texas 76065 R SPECIFICATIONS Portland Cement Type I/II (Low Alkali) A.S.T.M. C150-95 A.A.S.H.T.O. M 85-911 Bin Number Car Number Tons Date of Sampling July 1996 Monthly Average SPECIFICATIONS TEST ASTM AASHTO RESULTS CHEtVIlCAL REQUII~L1V11~NTS Silica Oxide, Minimum Percent 20.0 20.0 20.4 Alumina Oxide, Maximum Percent 6.0 6.0 4.6 Iron Oxide, Maximum Percent 6.0 6.0 3.9 Magnesia Oxide, Maximum Percent 6.0 6.0 1.2 S03 (C3A less than 8%), Maximum Percent 3.5 Loss on Ignition, Maximum Percent 3.0 3.0 1.0 Insoluble residue, Maximum Percent 0.75 0.75 0.19 Tricalcium Aluminate, Maximum Percent 8 8 6 OPTIONAL CHEMICAL RE QUIREMENTS Total Alkalies, Max. % {Na20 equiv.) 0.60 0.60 0.41 PHYSICAL REQUlREM EN'~$ Specific surface, Minimum (M"2/Kg) 280 280 Blaine Maximum (M"2/Kg) 400 347 Gillmore, Initial Set, Minimum (Minutes) 60 60 168 Gillmore, Final Set, Maximum (Minutes) 600 600 299 Vicat, Minimum (Minutes) 45 45 Initial Set Maximum (Minutes) 375 375 98 Air Content, Volume Maximum Percent 12 12 6 Autoclave Expansion, Maximum Percent 0.80 0.80 0 3 Day Minimum Compressive Strength, PSI 1800 1800 3190 7 Day Minimum Compressive Strength, PSI 2800 2800 4169 STATE OF TEXAS J.R. Owens ,being duly sworn deposes and says; that he is Chief Chemist of Texas Industries, Cement Division, who prepared the above report of tests and that the same is true and correct. Subscrib and sworn to before me this 8th day of August, 1996. N tary Public Ch' Chemist ELLIS COUNTY "See ASTM C150 Table 1, Footnote B. ~PPY Pie K C COKER so ~~~ * * Notary Public m~~ +~y STATE OF TEXAS My Comm. Exp. 10/22/98 Specific product information can be found 24-hours a day on the In Grace Construction Products W.R. Grace & Co. -Conn. 4323 Crites Street P.O. Box 2585-77252 Houston, TX 77003 March 29, 1996 Texas Industries 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that Daravair 1000, an air-entraining admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specification for Air-Entraining Admixtures for Concrete, ASTM Designation: C260 (AASHTO M154). Daravair 1000 does not contain calcium chloride containing compounds as a functional ingredient. Chloride ions may be present in trace amounts contributed from the domestic water supply used during the manufacturing process. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The foregoing is in addition to and not in substitution for our standard Conditions of Sales printed on the reverse side hereof . Sincerely, Tom C. Henson District Manager Subscribed and sworn to, before me, this 29th day of March, 1996 A.D. ary ~up~ic Q o_ . VJACHEL Notary Public, Sfate of Texas Y My Comm'sssian Expires 10-20-97 • • We hope the information given here will be helpful. It is hosed on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sole which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any potent or copyright. Grace Construction Products W.R. Grace & Co. -Conn. 4323 Crites Street P.O. Box 2585-77252 Houston, TX 77003 March 29, 1996 Texas Industries 1341 W. Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that WRDA with HYCOL, a water-reducing admixture, as manufactured and supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, Type A (AASHTO M194, Type A). No chlorides or halogens are added to WRDA with HYCOL as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof. S'ncerely, 1 F%E , Per Tom C. Henson District Manager Subscribed and sworn to, before me, this 29th day of March, 1996 A.D. ~ n~ ~ ~ ~~ Notary ulplic -F.~ A _,-. t ,. We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statemeMS, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend Ihe~~i os a recommendation for any use which would infringe any potent or copyright. Grace Construction Products W.R. Grace & Co. -Conn. 4323 Crites Street P.O. Box 2585-77252 Houston, TX 77003 March 29, 1996 Texas Industries 1341 Mockingbird Lane Dallas, TX 75247 Gentlemen: This is to certify that DARATARD-17, a water-reducing set- retarding admixture, supplied by the Construction Products Division, W.R. Grace & Co.-Conn., is formulated to comply with Specifications for Chemical Admixtures for Concrete, ASTM Designation: C-494, as a Type B & D admixture; and the Standard Specifications of the Texas Highway Department. No chlorides or halogens are added to DARATARD-17 as functional ingredients during manufacture. Material supplied for the above referenced project is identical in all respects, including concentration, to the one originally submitted to and approved by the State of Texas, Dept. of Transportation. The above is in addition to and not in substitution for our standard Conditions of Sale printed on the reverse side hereof . S' cerel , Tom C. Henson District Manager Subscribed and sworn to, before me, this 29th day of March, 1996 A.D. c ~DOL~LY^,!. lrJkCHEL • Notary Fublic, State of Texas AAy ~err°,missEon Expires ?u-2o-5~ • ~.....~..,.~~ t r We hope the information given here will be helpful. It is based on our best knowledge, and we believe it to be true and accurate. Please read all statements, recommendations or suggestions herein in conjunction with our conditions of sale which apply to all goods supplied by us. We assume no responsibility for the use of these statements, recommendations, or suggestions, nor do we intend them as a recommendation for any use which would infringe any patent or copyright. TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 0207/96 #ALL Tests Production Facility: BRIDGEPORT Size #: 57 Grading Designation: ASTM C-33 1 " - #4 Project: ***** ALL JOBS ***** Sample Location: Sieve S' a Cumulative Wt.- eta' ed Cumulative 9o Reta' Cumulative ass' .Required Spe 9' etai ed cification % ss' 2 0" 5" ,0~' 2 98.28 0 - 5 5 - 00 3 4" 6 82.54 2 " 5.43 44.57 40 - 75 25 - 60 3 8 " 79.30 20.70 4 9 0 .80 90 - 00 • 0- 0 8 8.83 1.17 95 - 100 0 - 5 #10 #16 #30 #40 #50 #100 #200 99.13 0.87 Pan Wt. Decant .89% Sampled By: Tested By: 100% of 151 tests: Size 57 Plant: BRIDGEPORT Job: ***** ALL JOBS ***** TEXAS INDUSTRIES, INC. QUALITY CONTROL DEPT. AGGREGATE SIEVE ANALYSIS Date: 02f07196 #ALL Tests Size #: 33 Project: ***** ALL JOBS ***** Production Facility: PARADISE Grading Designation: ASTM C-33 FINE AGG. Sample Location: Sieve S' a Cumulative eta' ed Cumulative % Retai ed Cumulative % ass' Required Specification q etained % Passin 2 0" 1.5" .0" 3 4" 1 2" 3 8" #4 1.78 98. 2 0 - 5 95 - 100 #8 18.99 81.01 0 - 20 80 - 100 #10 #16 35.01 64.99 15 - 50 50 - 85 #30 50.19 49.81 40 - 75 25 - 60 #40 #50 72.29 27.71 70 - 90 10 - 30 #100 95.16 4.84 90 - 98 2 - 10 #200 98.88 1.12 Pan Wt. 2.73 Fineness Modulus M.C. 6.1% Sampled By: ~~ Decant 1.03% S.E. 85.76 /J Tested By: Q.vC ~~.e~ 100% of 166 tests: Size 33 Plant: PARADISE Job: ***** ALL JOBS *****