Austin Place-LR 961112
Elierbee-Walczak, Inc, CONSTRUCTION MATERIALS TESTING C MPRESSIVE STRENGTH (6x12" CYL.) AND/OR FLEXURAL STRENGTH TEST (CENTERPOINT OR 3RD POINT) REPORT NO.: PROJECT: CLIENT: DATE OF PLACEMENT: CONCRETE SUPPLIER: STRENGTH REQ./28 DAYS: DESIGN ID #: TECHNICIAN: TEST ID # SLUMP AGE DATE AB1048cy. doc Austin Place #1915 Austin Bridge & Road i 1 /i 2/96 TXI 6sk 4000 psi Barton LOAD STRENGTH TYPE ADDN.INFO. X 1000 PSI 1 4.0 7 11/19 108.5 3838 Ticket 701914 2 7 11/19 113.0 3997 Truck 383 3 28 12/10 139.5 4935 Time 8:10 4 28 12/10 142.0 5023 Temp 73/Air 6.2 5 4.5 7 11/19 121.5 4298 Ticket 702508 6 7 11/19 117.5 4156 Truck 457 7 28 12/10 152.5 5394 Time 2:00 8 28 12/10 157.0 5554 Temp 78 LOCATIONS: Set 1 Austin Ct. Cul-de-sac Set 2 Homewood & Moore intersection Ronald A. Ellerbee, C.E.T. cc: Austin Coppetl ~~~ 6900 So. Freeway, Suite A-1 • Fort Worth, Texas 76134 Laboratory; (817) 293-0111 Fax: (817) 596-0941