Loading...
Austin Place-LR 961109 Ellerbee-Walczak, Inc. CONSTRUCTION MATERIALS TESTING COMPRESSIVE STRENGTH (6x12" CYL,} AND/OR FLEXURAL STRENG TH TEST (CENTERPOINT OR 3RD POINT} REPORT NO.: A81046cy.doc PROJECT: Austin Place #1915 CLIENT: Austin Bridge & Road DATE OF PLACEMENT: 11/9/96 CONCRETE SUPPLIER: TXI STRENGTH REQ./28 DAYS: 3000 DESIGN ID #: TECHNICIAN: Barton TEST LOAD STRENGTH TYPE ADDN.INFO. ID # SLUMP AGE DATE X 1000 PSI 1 2.5 7 11 /16 105.5 3732 Ticket 700510 2 7 11 /16 110.0 389 7 Truck 389 3 28 12/07 138.0 4881 Time 7:20 4 28 12/07 141.5 5005 Temp 65/Air 5.25 5 3.0 7 11/16 98.5 3484 Ticket 700535 6 7 11/16 95.5 3378 Truck 385 7 28 12/07 122.0 4316 Time 8:30 8 28 12/07 122.5 4333 Temp 67/Air 5.8 9 2.5 7 11/16 98.0 3467 Ticket 700554 10 7 11/16 100.5 3555 Truck 453 11 28 12/07 128.5 4545 Time 9:15 12 28 12/07 131.5 4652 Temp 67 13 2.5 7 11 /16 100.0 3537 Ticket 700576 14 7 11/16 103.0 3643 Truck 389 15 28 12/07 127.5 4510 Time 10:30 16 28 12/07 131.5 4652 Temp 69 17 3.5 7 11/16 96.0 3396 Ticket 7005 18 7 11!16 99.5 3520 Truck 452 19 28 12/07 127.5 4510 Time 11:25 20 28 12/07 123.5 4369 Temp 69 21 4.0 7 11/16 110.0 3891 Ticket 700617 22 7 11/16 109.5 3873 Truck 389 23 28 12/07 i 42.5 5041 Time 12:10 24 28 12/07 139.0 4917 Temp 68 25 4.0 7 11/16 108.0 3820 Ticket 700644 26 7 11/16 103.5 3661 Truck 455 27 28 12/07 138.5 4899 Time 1:15 28 28 12/07 136.0 4811 Temp 72/Air 5.8 LOCATIONS: Moore St. northbound lane Set 1 Sta. 26 + 00 Set 5 Sta. 18 + 50 Set 2 Sta. 24 + 50 Set 6 St 7 + 00 Set 3 Sta. 22 + 00 Set 7 ~ 14 + 00 Set 4 Sta. 26+00 ~ G~~ ~~ ~j~' ~ ~' Ronald A. Ellerbee, C.E.T. cc: Austin Coppelt 6900 So. Freeway, Suite A-1 • Fort Worth, Texas 76134 Laboratory: (817) 293-0111 Fax: (817) 596-0941