Loading...
Austin Place-LR 961031Ellerbee-Walczak, Inc, CONSTRUCTION MATERIALS TESTING REPORT NO.: AB10-12den.doc REPORT OF: 1n Place Densit}• Tests Utilizing Nuclear Gauge FOR: Austin Bridge & Road PROJECT: Austin Place #1911 DATE: 10/31/96 NO. PROC % MOIST. % DRY DEN LOCATIONS AT GRADE 1 2 17.7 97.8 Indian Rock Dr. Sta. U+~O 2 2 17.1 98.9 Sta.3+50 3 2 16. ~ 96.3 Sta. 6+50 -1 2 I8.6 97.-t Sta.9+50 2 17.5 99.9 Austin Ct. Cul-de-sac 6 2 1 ~.9 98.1 Home«~ood Dr. Sta. 6+50 7 2 16.8 97.7 Sta.3+50 R 1 16.5 96.8 Sta.0+5U 9 2 17.0 95.8 Moore Rd. N. bound Sta. 2~+50 10 1 16.3 96.2 Sta. 22+50 I1 1 16.-t 99.3 Sta. 19+50 12 1 15.4 97.5 Sta. 16+50 PROCTORS USED: #1 - 112.6 PCF ~u. 1.1.5°~~ #2 - 106.5 PCF ~h, 15.-I°~~ l~ Ronald A. Ellerbee, C.E.T. cc: Austin Coppell 6900 So. Freeway, Suite A-1 • Fort Worth, Texas 76134 Laboratory: (817) 293-0111 Fax: (817) 596-0941