Loading...
ST9902-LR061030 Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: Project: City of Coppell West Sandy Lake Road Reconstruction Report Distribution: (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins CMJ Report No.: 687-5192-162 Report Date: 11/20/2006 n/a 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method Test Data 10/18/2006 Josh Bridges Sunny Redi Mix/732 ASTM C231 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 3500 psi @ 28 Days 4 in max 3 % min 6 % max Ticket Number: Slump: Concrete Temperature: Placement Location: 178201 Time Batched: N/A 4 in Air Content: 5.4 % 790 F Ambient Temperature: 800 F Median: Stamped Concrete, 15' South of Sandy Lake/Freeport Intersection Time Sampled: 11:10 Unit Weight: N/A Yardage (c.y.): 9 of 9 Sample Location: Median: Stamped Concrete, 15' South of Sandy Lake/Freeport Intersection Concrete Compression Test Results Cylinder Age Max Load, Area Strenth Fracture Set# # Test Date (days) (Ibs. force) (sq.in.) (pSI Type 01 SLR10180601 1 0/25/2006 7 105980 27.99 3790 E-columnar 01 SLR10180602 11/15/2006 28 128780 28.18 4570 C-cone/shear 01 SLR10180603 11/15/2006 28 131500 28.18 4670 C-cone/shear 01 SLR10180604 Hold 28 day average 4620 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. o Gallons of Water Added On-Site CMJ Engineering, 'nc R. Carl Lee, S.E.T. Vice PresidentlCMT Manager LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 Page I of I Concrete Compression Test Report eM J ENGINEERING, INC. 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (817) 284-9400 Fax: (817) 589-9993 Client: City of Coppell ,// Report Distribution: Project: West Sandy Lake Road , . Reconstruction (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins CMJ Report No.: 687-5192-162 Report Date: 10/30/2006 3 % min 6 % max n/a 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method Test Data 10/18/2006 Josh Bridges Sunny Redi Mix/732 ASTM C231 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications 3500 psi @ 28 Days 4 in max Ticket Number: Slump: Concrete Temperature: Placement Location: 178201 Time Batched: N/A 4 in Air Content: 5.4 % 790 F Ambient Temperature: 800 F Median: Stamped Concrete, 15' South of Sandy Lake/Freeport Intersection Time Sampled: 11:10 Unit Weight: N/A Yardage (c.y.): 9 of 9 Sample Location: Median: Stamped Concrete, 15' South of Sandy Lake/Freeport Intersection Concrete Compression Test Results Cylinder Max Load Area ~ Fracture Set # # Test Date ~ (Ibs. force) (sq.in.) Type 01 SLR10180601 1 0/25/2006 7. 105980 27.99 3790 E-columnar 01 SLR10180602 11/15/2006 , ' 28 " 01 SLR 1 0180603 11/15/2006 01 SLR 10180604 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. o Gallons of Water Added On-Site II' I';O~ CMJ Engineering, 'nc LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and areas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 Page I of I