Service Star-LR061013
FIELD DENSITY TESTING
Report Number: 94061329.0004
Service Date: October 5, 2006
lrerracon
8901 Carpenter Frwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client:
ServiceStar Design Group LLC
Attn: Frank Malek
5670 Greenwood Plaza Blvd, Suite 300
Greenwood Village CO 80111
Report Date:
Project:
October 13, 2006
Multi-Facility Concept
(Firestone Store) V'/ stlllb/#/1(. UJ 7 -f?'
SWC Hwy. 121 & MacArthur Blvd.
Coppell, TX
94061329
Project No.:
Description and Classification
Dark brown elay
Lab Test Data
Optimum Max. Lab
Water Dry Unit
Content Weight
(%) (pet)
20.6 98.6
Proieet Requirements
Material Information
Material
No.
Laboratory
Test Method
Water
Content
(%)
>1= +4
Minimum Dry
Unit Weight
(% compaction)
1 613290002 ASTM D 698
Field Test Data
Test
No.
92
Test Location
Probe Water Dry Unit Dry Unit
Li ftl Mat. Depth Content Weight Weight
Elev. No. (inches) (%) (pet) (% compaction)
8' BFF 6 25.8 92.3 94
8' BFF 6 26.1 92.6 94
Building Pad, Moisture Conditioned
1 D.5/3.5
2 E.8/3.9
Datum: BFF = below finished floor
Comments:
Test results on this report meet project specification.
Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture
condition.
Field Test Method: ASTM D-2922, ASTM D-3017
Gauge ID: 32769
Terracon Rep: J.Craig Blackwell
Field Results Reported To: Conctractor-Superintendent, Ke
Report Distribution:
(1) ServiceStar Design Group LLC
(1) City of Coppel! TX
(1) City of Coppel! TX
(1) ICI Construction Inc
(1) ICI Construction Inc
(1) Pate Engineers
(1) ServiceStar Design Group LLC
(1) Ratliff Group LLC
Reviewed by:
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1
Q7-PDRIR07.FutL're Key
REPORT OF IN-PLACE DENSITY TESTING
Report Number: 94061329.0006
Service Date: October 7,2006
lrerracon
8901 Carpenter F rwy, Ste #100
Dallas, Texas 75247
(214) 630-1010
Client:
ServiceStar Design Group LLC
Attn: Frank Malek
5670 Greenwood Plaza Blvd, Suite 300
Greenwood Village CO 80111
Report Date:
Project:
October 13, 2006
Multi-Facility Concept
(Firestone Store)
SWC Hwy. 121 & MacArthur Blvd.
Coppell, TX
94061329
Project No.:
Services: In-place density testing.
On this date, Terracon's representative arrived at the above referenced job site as scheduled for
in-place density tests. After arriving at the job site, Terracon's representative was notified that
in-place density tests were cancelled due to no one at job site.
",,;"".
f:/!~
/ri7'~
.~
1ft
I'
Terracon Rep: Christopher D. Harbour
Report Distribution:
(1) ServiceStar Design Group LLC
(1) City of Coppel! TX
(1) City of Coppel! TX
(1) ICI Construction Inc
Lyndo Cox, P.E.
Princ pa Engineer
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for e use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
(1) ICI Construction Inc
(1) Pate Engineers
(1) ServiceSlar Design Group LLC
(1) Ratliff Group LLC
Reviewed by:
Page 1 of 1
9g..PDR/R99-Future Key