Coppell/121 Off Pk-LR040719~' ACTEC
J
ENGINEERING AND CONSULTING
MACTEC Engineering
and Consulting
2200 Gravel Drive
Fort Worth, Texas 76118-7123
Tel: 817-284-7755• Fax: 817-589-1420
REPORT OF
IN-PLACE DENSITY
CLIENT: SALYER AND ASSOCIATES
2557 SOUTHWEST GRAPEVINE PKWY PAGE 1 OF 1
SUITE 200
GRAPEVINE, TX 76051 PROJECTNO.: 9023747
REPORT NO.: 4 0 4 8 5 2
PROTECT: HWY 121 BUSINESS PARK DATE OF SERVICE: 7 / 12 / 2 0 04
AUTHORIZATION:
REPORT DATE: 7/19/2004
SERVICES: Perform in-place density and moisture content tests to determine the degree
of field compaction.
CONTRACTOR: SALYER AND ASSOCIATES
METHOD OF TEST:
DENSITY: ASTM D2922
MOISTURE: ASTM D3017
SPECIFICATION:
DENSITY: 9 5 $
MOISTURE: 0 TO +4 $ OF OPT .
PROJECT DATA
GAUGE:TROXLER 3430B
GAUGE SERIAL NO.: 2 3 3 3 4
STANDARD COUNTS
MOISTURE - CURRENTi~IA PREVIOUS: NA
DENSITY - CURRENT:NA PREVIOUS: NA
TEST MODE: Direct Transmission
PROBE DEPTH (in.): 6
MOISTURE/DENSITY RELATIONS REFERENCE
TEST OF MATERIALS MOISTURE % DENSITY pcf REPORT NO
ON SITE LT.BROWN CALICHE CLAY 22.5 98.5 404813
ON SITE Brn & Drk Brn Clay 19.5 104.0 404403
TEST
NO LOCATION
1. BACKFILL PARALLEL WITH 121 FOR
~~"PARKING AREA~TORTH 1ST LIFT
. 2. `~ SAME @ SOUTH 1ST LIFT
3. SAME @ NORTH 2ND LIFT
REPORT OF TESTS
FIELD OPTIMUM FIELD DENSITY MAXIMUM
MOISTURE MOISTURE (pcfj DENSITY DENSITY
(%) (%) WET DRY (Pcf1 (% max)
24.5 22.5 119.5 96.0 98.5 97
21.8 19.5 122.4 100.5 104.0 97
24.7 22.5 120.2 96.4 98.5 98
4. SAME @ SOUTH 2ND LIFT 21.5 19.5 123.0 101.2 104.0 97
Test results on this report meet project
specifications as noted above.
Technician: Scott Jaeger Started: 03:OOPM Stopped: 05:OOPM
Report Distribution:
li) SALYER AND ASSOCIATES AC' E~,'
(11 CITY OF COPPELL
Tim Begole, CET.
Our letters and reports are for the exclusive use of the client to whom they are addressed and shall twt be reproduced except in
full wit}tout the approval of the testing laboratory. The use of our rtatne must receive our written approval. Our letters and reports
I O07 TT apply only to the sample tested and/or inspected, and are not indicative of the quantities of apparently identical or similar products.