Loading...
Deer Run-LR000324CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 41 7 03/29/00 81000 2870 4000/28 days DRC 42 28 02/23/00 125000 4420 DRC 43 28 03/23/00 123000 4350 DRC 44 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C Methods: ASTM C -39 Fracture mode Types of Fracture: A is (A) unless otherwise noted 't ra g ll C D FUGRO SOUTH, INC. REMARKS: SMH /rm Distribution: COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 24, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Technician: Dumitru Balas Ryland Homes Philip Flink City of Coppell Garth Campbell Gilco Mark Leonard Gilco Contracting 474091 68 66 9:09 am 9:40 am Cloudy Sidewalk on intersection Hawkins Drive north with Hawkins Drive west CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (ASTM C -231) WATER ADDED (gal): 0 SLUMP (in.) (ASTM C -143) 4 FUGRO SOUTH INC. Reviewed By: 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: March 24, 2000 PROJECT NO: 0791 -2308 Pioneer Concrete 27/924 7724 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 37 7 03/01/00 104000 3680 3600/28 days DRC 38 28 03/22/00 124000 4390 DRC 39 28 03/22/00 127000 4490 DRC 40 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode Types of Fracture: A is (A) unless otherwise noted OVA Z FA B c D FUGRO SOUTH, INC. COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 23, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: REMARKS: Technician: Thomas Cranford SMH /rm Distribution: Ryland Homes Philip Flink City of Coppell Garth Campbell M.B. Structures 083747 CONCRETE SUPPLIER: 61 PLANT/TRUCK: 78 MIX ID NUMBER: 10:13 AIR (ASTM C 231) 11:10 WATER ADDED (gal): Cloudy SLUMP (in.) (ASTM C 143) Storm drain #1 on left side of Hawkins Drive FUGRO SOUTH INC. Reviewed By:_ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: March 24, 2000 PROJECT NO: 0791 -2308 Lattimore 7/1093 42 0 2 3/4 GOO