Deer Run-LR000302CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS
Standard 6" x 12 28.27 square inches
CYLINDER
NUMBER
AGE
(days)
DATE
TESTED
TOTAL
LOAD
(pounds)
COMPRESSIVE
STRENGTH
(psi)
SPECIFIED COMPRESSIVE
STRENGTH
(psi)
DRC 37
7
03/01/00
104000
3680
3600/28 days
DRC 38
28
03/22/00
DRC 39
28
03/22/00
DRC 40
Hold
Specifications:
Making ASTM C -31
Curing:
Testing ASTM C -143,
Methods: ASTM C -39
Fracture mode
Types of
Fracture: A
is (A) unless otherwise noted
B C/ D
FUGRO SOUTH, INC.
COMPRESSIVE STRENGTH OF CONCRETE REPORT
CLIENT: Ryland Homes
PROJECT: Deer Run, Coppell, Texas
SAMPLE DATE: February 23, 2000
CONTRACTOR:
TICKET NO.:
AMBIENT TEMP. °F):
CONCRETE TEMP. °F) (ASTM C 1064):
TIME BATCHED:
TIME SAMPLED:
WEATHER CONDITION:
LOCATION OF PLACEMENT:
REMARKS:
Technician: Thomas Cranford
SMH /rm
Distribution: Ryland Homes Philip Flink
City of Coppell Garth Campbell
M.B. Structures
083747
61
78
10:13
11:10
Cloudy
Storm drain #1 on
FUGRO SOUTH INC.
2880 Virgo Lane; Dallas, Texas 75229
Ph (972) 484 -8301; Fax (972) 620 -7328
REPORT DATE: March 2, 2000
PROJECT NO: 0791 -2308
CONCRETE SUPPLIER:
PLANT/TRUCK:
MIX ID NUMBER:
AIR (ASTM C 231)
WATER ADDED (gal): 0
SLUMP (in.) (ASTM C -143)
left side of Hawkins Drive
Lattimore
7/1093
42
2 3/4
Reviewed