Deer Run-LR000229CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 33 7 02/28/00 80000 2830 4000/28 days DRC 34 28 03/20/00 DRC 35 28 03/20/00 DRC 36 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode Types of Fracture: A is (A) unless otherwise noted gli rA B L C D FUGRO SOUTH, INC. COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 21, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: REMARKS: Technician: Dumitru Balas S M H /rm Distribution: Ryland Homes Philip Flink City of Coppell Garth Campbell Gilco Mark Leonard Gilco Contracting 473925 60 60 9:36 am 10:10 am Cloudy CONCRETE SUPPLIER: Pioneer Concrete PLANT/TRUCK: 27/807 MIX ID NUMBER: 7724 AIR (ASTM C 231) 6 WATER ADDED (gal): 10 SLUMP (in.) (ASTM C 143) 7 Paving, on intersection west Hawkins Drive with south Hawkins Drive FUGRO SOUTH INC. Reviewed By: GIRO LTLIP im 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: February 29, 2000 PROJECT NO: 0791 -2308