Loading...
Deer Run-LR000225CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 29 7 02/23/00 82000 2900 4000/28 days DRC 30 28 03/15/00 DRC 31 28 03/15/00 DRC 32 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode Types of Fracture: A is (A) unless otherwise noted B C D FUGRO SOUTH, INC. COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 16, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: REMARKS: Technician: Dumitru Bales SMH /rm Distribution: Ryland Homes Philip Flink City of Coppeil Garth Campbell Gilco Mark Leonard Gilco Contracting Co. 473644 CONCRETE SUPPLIER: 63 PLANT/TRUCK: 62 MIX ID NUMBER: 1:15 pm AIR (ASTM C 231) 1:50 pm WATER ADDED (gal): Cloudy SLUMP (in.) (ASTM C 143) Paving: Alley 2, station 8 +75 FUGRO SOUTH INC. Reviewed By: 2880 Virgo Lane: Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: February 25, 2000 PROJECT NO: 0791 -2308 Pioneer Concrete 27/823 7724 7 5 6 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 25 7 02/03/00 84000 2970 4000/28 days DRC 26 28 03/15/00 DRC 27 28 03/15/00 DRC 28 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode is (A) unless otherwise noted Types of Fracture: A V B C D A FUGRO SOUTH, INC. CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 16, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: REMARKS: SMH /rm Distribution: COMPRESSIVE STRENGTH OF CONCRETE REPORT Technician: Dumitru Balas Ryland Homes Philip Flink City of Coppell Garth Campbell Gilco Mark Leonard Gilco Contracting Co. 441145 CONCRETE SUPPLIER: 60 PLANT/TRUCK: 66 MIX ID NUMBER: 7:53 am AIR (ASTM C -231) 8:30 am WATER ADDED (gal): Cloudy SLUMP (in.) (ASTM C -143) Paving: Alley A2, station 0 +50 FUGRO SOUTH INC. Reviewed By:_ Pioneer 27/29 7724 6 10 5.50 �GRO J GI fl 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: February 25, 2000 PROJECT NO: 0791 -2308