Loading...
Deer Run-LR000221CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 13 7 02/21/00 101000 3570 3000/28 days DRC 14 28 03/13/00 DRC 15 28 03/13/00 DRC 16 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode Types of Fracture: A is (A) unless otherwise noted vi Fi B k c D FUGRO SOUTH, INC. CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 14, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C- 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: REMARKS: COMPRESSIVE STRENGTH OF CONCRETE REPORT Technician: Dumitru Balas S M H /rm Distribution: 441052 59 76 2:30 pm 3:00 pm Ryland Homes Philip Flink City of Coppell Garth Campbell Gilco Mark Leonard Gilco Contracting Co. CONCRETE SUPPLIER: PLANT/TRUCK: MIX ID NUMBER: AIR (ASTM C -231) WATER ADDED (gal): SLUMP (in.) (ASTM C -143) Paving on Hawkins Drive south, station 3 +50 FUGRO SOUTH INC. Reviewed By: 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 REPORT DATE: February 21, 2000 PROJECT NO: 0791 -2308 Pioneer Concrete 27/749 7718 5.9 10 3 CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) DRC 9 7 02/21/00 84000 2970 3000/28 days DRC 10 28 03/13/00 DRC 11 28 03/13/00 DRC 12 Hold Specifications: Making ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode Types of Fracture: A! is (A) unless otherwise noted D 11 11 B C FUGRO SOUTH, INC. REMARKS: SMH /rm Distribution: 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Ryland Homes PROJECT: Deer Run, Coppell, Texas SAMPLE DATE: February 14, 2000 CONTRACTOR: TICKET NO.: AMBIENT TEMP. °F): CONCRETE TEMP. °F) (ASTM C 1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Technician: Dumitru Balas Ryland Homes Philip Flink City of Coppell Garth Campbell Gilco Mark Leonard Gilco Contracting 441034 CONCRETE SUPPLIER: 53 PLANTITRUCK: 56 MIX ID NUMBER: 12:20 pm AIR (ASTM C 231) 12:50 pm WATER ADDED (gal): Sunny SLUMP (in.) (ASTM C -143) Paving on Hawkins Drive west station 1+00 FUGRO SOUTH INC. Reviewed By: GOO REPORT DATE: February 21, 2000 PROJECT NO: 0791 -2308 Pioneer Concrete 27/931 7718 5.6 5 2 3/4