DR8801-LR 881104Gifford-Hill & Company, Inc. A member of THE BRAZER GROUP 240 SINGLETON BLVD · DALLAS, TEXAS 75212 (Mait Address: P O Box 655688 · Dallas, Texas 75265-5688) PHONE 214/748-8061 61FFORD.HILL CONCRETE DIVISION November 4, 1988 TO: Buckalew Construction PROJECT: Drain Improvements-Coppell SUBJECT: Proposed Mix Design SALESPERSON ~eith Woodson Gentlemen: We are pleased to submit the following on the above referenced pro3ect. Please use our GHS# concrete. MIX DESIGN PROPORTIONS - ONE CUBIC YARD Specified 28 day Strength (f'c) Mix Number mix designs for your approval when ordering (SSD) ~ 3000 PSI GHS# 8 Cement Type I Flyash Class C 1" #4 Aggregate Sand Water Water Reducing Admix Air Entraining Agent Superplasticizing Admix DESIGN MIX CHARACTERISTICS 470 lbs lbs 1850 lbs lbs 1518 lbs 246 lbs 14.1 ozs 0.0 ozs ozs COMPRESSIVE STRENGTH, PSI - From Historical Data Slump Inches 3 - 5 Unit Wt. - lb/CF (plastic) 151.4 Test Age W/C Ratio - lb/lb .52 3 - Day Air Content - % 1.0-2.0 7 - Day Flyash - %/WT 28 - Day The above mlx design is 5084 guaranteed to achleve specified compressive strength when tested and evaluated in accordance with applicable ASTM and ACI test methods and specification. We would appreciate notification of mix design approval before commencement of concrete placement. Please do not hesitate to Gall if you have any questlon concerning the mix design data. ~espectfu~y~mltted, Frank ~ic~olaus Quality Control Manager Gifford-Hill & Company, Inc. A member of THE BEAZER GROUP 240 SINGLETON BLVD · DALLAS, TEXAS 75212 (Mail Address: PO Box 655688 · Dallas, Texas75265-5688) PHONE 2 ~ 4/748-8061 61FFORD'HILL CONCRETE DIVISION November 4, 1988 TO: Buckalew Construction PROJECT: Drain Improvements-Coppell SUBJECT: Proposed Mix Design SALESPERSON - Keith Woodson Gentlemen: We are pleased to submit the following mix designs for your approval on the above referenced pro3ect. Please use our GHS# whe~ ordering concrete. PROPORTIONS - MIX DESIGN ' ONE CUBIC YARD (SSD) Specified 28 day Strength (f'c) 3000 PSI Mix Number GHS~ 18 Cement Type I 470 lbs., Flyash - Class C lbs. 1" - #4 Aggregate 1850 lbs. lbs. Sand 1425 lbs. Water 240 lbs. Water Reducing Admix 14.1 ozs. Air Entraining Agent 2.1 ozs. Superplasticizing Admix ozs. DESIGN MIX CHARACTERISTICS COMPRESSIVE STRENGTHt PSI - From Historical Data Slump Inches 3 - 5 Unit Wt. - lb/CF (plastic) 147.6 Test Age W/C Ratio lb/lb .51 3 - Day Air Content - % 3.0-6.0 7 - Day Flyash - %/WT 28 - Day 4253 The above mix design is guaranteed to achieve specified compressive strength when tested and evaluated in accordance with applicable ASTM and ACI test methods and specification. We would appreciate notification of mix design approval before commencement of concrete placement. Please do not hesitate to call if you have any question concerning the mix design data. Res pect~ u l~.~itt ed, Frank Nickolaus Quality Control Manager Gifford-Hill & Company, Inc. A member of THE BEAZER GROUP 240 SINGLETON BLVD · DALLAS TEXAS 75212 (Mail Address: P O. Box 655688 · Dallas, Texas 75265-5688) PHONE 214/748-8061 GIFFORD'HILL CONCRETE DIVISION November 4, 1988 TO: Buckalew Construction PROJECT: Drain Improvements-Coppell SUBJECT: Proposed Mix Design SALESPERSON Keith Woodson Gentlemen: pleased to submit the following mix designs for your approval Please use our GHS# when ordering/ MIX DESIGN PROPORTIONS - ONE CUBIC YARD (SSD) ~ / We are on the above referenced pro3ect. concrete. 4000 PSI GHS# 20 Specified 28 day Strength (~'c) Mix Number Cement Type I Flyash - Class C 1" #4 Aggregate Sand Water Water Reducing Admix Air Entraining Agent Superplasticizing Admix 564 lbs. lbs. 1850 lbs. lbs. 1341 lbs. 242 lbs. 16.9 ozs. 2.5 ozs. DESIGN MIX CHARACTERISTICS Slump - Inches 3 - 5 Unit Wt. lb/CF (plastic) 148.0 W/C Ratio - lb/lb .43 Air Content - % 3.0-6.0 Flyash %/WT COMPRESSIVE STRENGTH, PSI - From Historical Data Test Age 3 - Day ? - Day 28 - Day 4998 The above mix design is guaranteed to achieve specified compressive strength when tested and evaluated in accordance with applicable ASTM and ACI test methods and specification. We would appreciate commencement of concrete placement. you have any question concerning the notification of mix design approval before Please do not hesitate to call if mix design data. Respectfu~y~bmitted, Frank Nlckolaus Ouality Control Manager