SC-Coppell MSW-LR020808 (3) FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: CoppelllSD, c/o K A Sparks Coppell Middle School West, Coppell, Texas Report Date: August 8, 2002 Project No.: 0701-2192 SAMPLE DATE: July 26,2002 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (OF): CONCRETE TEMP. (OF) (ASTM C-1064): TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Cortez Group, Inc. 189758 CONCRETE SUPPLIER: Hanson 85 PLANT/TRUCK: 27/1888 84 MIX 10 NUMBER: 9351 6:40 am AIR (%) (ASTM C-231) : 5.5 7:30 am WATER ADDED (gal): 5 Sunny SLUMP (in.) (ASTM C-143) : 5 1/2 Parking lot next to Building A from west end of parking lot go to 60 ft. east, and from north go 10ft. south CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMS 249 7 08/02/02 89920 3180 4000/28 days CMS 250 28 08/23/02 CMS 251 28 08/23/02 CMS 252 Hold Fracture mode is (A) unless othelWise noted Specifications: Making & ASTM C-31 Testing ASTM C-143, Types of A~ B~ clZl DO Curing: Methods: ASTM C-39 Fracture: REMARKS: Technician: Julio Villarreal FUGRO SOUTH INC. Reviewed By; ..--,1 --, SMH/rm Distribution: K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Jerry Jones (Fax: 972-393-1228) City of Coppell - Lee Stone City of Coppell - Garreth Campbe~ Coppell ISD - Mickey Harper SHW Group - Mike Elmore SHW Group - Dale Lilljedahl FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484-8301; Fax (972) 620-7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: PROJECT: CoppelllSD, c/o K A Sparks Coppell Middle School West, Coppell, Texas Report Date: August 8, 2002 Project No.: 0701-2192 SAMPLE DATE: July 26,2002 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (OF): CONCRETE TEMP. (OF) (ASTM C-1064): TIME BATCH ED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: Cortez Group, Inc. 189751 CONCRETE SUPPLIER: 78 PLANT/TRUCK: 76 MIX 10 NUMBER: 4:55 am AIR (%) (ASTM C.231) : 5:10am WATER ADDED (gal): Clear SLUMP (in.) (ASTM C-143) : Wrangler Circle next to existing parking lot Hanson 77/698 9351 6.0 5 5 CONCRETE CYLlNDERCOMPRESSNE STRENGTH TESTS Standard 6" x 12", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER AGE DATE LOAD STRENGTH STRENGTH NUMBER (days) TESTED (pounds) (psi) (psi) CMS 245 7 08/02/02 93550 3310 4000/28 days CMS 246 28 08/23/02 CMS 247 28 08/23/02 CMS 248 Hold Fracture mode is (A) unless othelWise noted Specifications: Making & ASTM C-31 Testing ASTM C-143. Types of A~ B~ clZl DO Curing: Methods: ASTM C-39 Fracture: REMARKS: Technician: Julio Villarreal FUGRO SOUTH INC. Reviewed By: ----; . SMH/rm Distribution; K A Sparks Contractors Inc. - Jim Schooler K A Sparks Contractors Inc. - Jerry Jones (Fax: 972-393-1228) City of Coppell - Lee Stone City of Coppell - Garreth Campbell CoppelllSD - Mickey Harper SHW Group - Mike Elmore SHW Group - Dale Lilljedahl