Loading...
SC-Coppell MSW-LR011112FUGRO SOUTH, INC. FIELD DENSITY REPORT �IGRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 CLIENT: Coppell ISD REPORT DATE: November 12, 2001 PROJECT: Coppell ISD Service Center, Coppell, Texas PROJECT NO 0701 - 2233 DATE PERFORMED: November 1, 2001 Density Test Method: ASTM D -2922 & 3017 Method of Compaction: ASTM D -698 MOISTURE /DENSITY RELATIONS Material Proctor Results Number Description Maximum Dry Density (pcf) Optimum Moisture ( %} 4 Dark brown clay 97.3 23.4 TEST RESULTS TEST PROCTOR LOCATION UNIT DRY MOISTURE PERCENT OF NO. NO. WEIGHT CONTENT PERCENT MAXIMUM DENSITY 18 4 8 inch sanitary sewer, Line B, station 96.9 21.3 99.5 0 +00, 3 feet below grade 19 4 8 inch sanitary sewer, Line B, station 94.8 22.7 97.4 0 +00, 1 foot below grade 20 4 8 inch sanitary sewer, Line B, station 95.4 22.0 98.0 0 +00, final 21 4 8 inch sanitary sewer, Line B, station 93.2 25.1 95.7 3 +00, 2 feet below grade 22 4 8 inch sanitary sewer, Line B, station 94.3 23.4 96.9 3 +00, final 23 4 8 inch sanitary sewer, Line B, station 95.8 21.5 98.4 6 +00, final 24 4 8 inch sanitary sewer, Line B, station 96.4 21.1 99.1 9 +00, final 25 4 8 inch water line, Line B, station 9 +00, 2 95.1 22.2 97.7 feet below grade 26 4 8 inch water line, Line B, station 9 +00, 99.1 24.0 96.7 final Remarks: All densities meet project specifications unless otherwise noted. James Spriggs Fugro South Technician FUGRO SOUTH INC. Reviewed By: SMH /bg Distribution: K A Sparks Contractors Inc. — Jim Schooler K A Sparks Contractors Inc. — Rick McKinney (Fax: 972 - 462 -9320) City of Coppell - Lee Stone City of Coppell - Garreth Campbell Coppell ISD - Mickey Harper SHW Group — Mike Elmore SHW Group — Dale Lilljedahl