Loading...
SC-Coppell MSW-LR011001FUGRO SOUTH, INC. �G R 51 2880 Virgo Lane; Dallas, Texas 75229 Ph(972)484 -8301; Fax(972)620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD, c/o K A Sparks Report Date October 1, 2001 PROJECT Coppell Middle School West, Coppell, Texas Project No .: 0701 - 2192 SAMPLE DATE: September 21, 2001 CONTRACTOR: TICKET NO.: AMBIENT TEMP. (°F): CONCRETE TEMP. (°F) (ASTM C - 1064) TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K.A. Sparks Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER 933866 CONCRETE SUPPLIER: Hanson 72 PLANT/TRUCK: 27/827 83 MIX ID NUMBER: 9351 8:28 a.m. AIR ( %) (ASTM C -231) : 5.5 9:00 a.m. WATER ADDED (gal): - Mostly Cloudy SLUMP (in.) (ASTM C -143) : 6 Paving Approach at driveway between stadium and middle school with Wrangler Road. Sampled at east half CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (p CMS 33 3 09 -24 -01 72600 2570 3600/28 days CMS 34 7 09 -28 -01 83000 2940 CMS 35 28 10 -19 -01 CMS 36 28 10 -19 -01 CMS 37 Specifications: Hold Making & ASTM C -31 Curing: Fracture mode is (A) unless otherwise noted Testing ASTM C -143, Types of Methods: ASTM C -39 Fracture: A® B® C Z D REMARKS: Technician: Jose Rivera FUGRO SOUTH INC. Reviewed By: SMH /bg Distribution: K A Sparks Contractors Inc. — Jim Schooler K A Sparks Contractors Inc. — Jerry Jones (Fax: 972 - 393 -1228) City of Coppell - Lee Stone City of Coppell - Garreth Campbell Coppell ISD - Mickey Harper SHW Group — Mike Elmore SHW Group — Dale Lilljedahl FUGRO SOUTH, INC. 2880 Virgo Lane; Dallas, Texas 75229 Ph(972)484 -8301; Fax(972)620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD, c/o K A Sparks Report Date: October 1, 2001 PROJECT Coppell Middle School West, Coppell, Texas Project No .: 0701 -2192 SAMPLE DATE: September 21, 2001 CONTRACTOR: TICKET NO.: AMBIENT TEMP. ( °F): CONCRETE TEMP. ( °F) (ASTM C -1064) TIME BATCHED: TIME SAMPLED: WEATHER CONDITION: LOCATION OF PLACEMENT: K.A. Sparks 933875 CONCRETE SUPPLIER: Hanson 74 PLANT/TRUCK: 27/829 85 MIX ID NUMBER: 9351 9:30 a.m. AIR ( % ) (ASTM C -231) : 5.0 10:10 a.m. WATER ADDED (gal): - Partly Cloudy SLUMP (in.) (ASTM C -143) : 5 -3/4 Paving for west parking lot, north addition. Sampled at 50 feet west and 10 feet south of northeast corner CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches CYLINDER NUMBER AGE (days) DATE TESTED TOTAL LOAD (pounds) COMPRESSIVE STRENGTH (psi) SPECIFIED COMPRESSIVE STRENGTH (psi) CMS 38 3 09 -24 -01 84500 2990 3600/28 days CMS 39 7 09 -28 -01 96600 3420 CMS 40 28 10 -19 -01 CMS 41 28 10 -19 -01 CMS 42 Hold Specifications: Making & ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode is (A) unless otherwise noted Types of Fracture: A® B® C Z D REMARKS: Technician Jose Rivera FUGRO SOUTH INC. Reviewed By: SMH /bg Distribution K A Sparks Contractors Inc. — Jim Schooler K A Sparks Contractors Inc. — Jerry Jones (Fax: 972 - 393 -1228) City of Coppell - Lee Stone City of Coppell - Garreth CampbelF Coppell ISD - Mickey Harper SHW Group — Mike Elmore SHW Group — Dale Lilljedahl