Loading...
SC-Coppell MSW-LR011019FUGRO SOUTH, INC. �fsRO ■ 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT: Coppell ISD, c/o K A Sparks Report Date October 19, 2001 PROJECT Coppell Middle School West, Coppell, Texas Project No .: 0701 -2192 SAMPLE DATE: October 4, 2001 CONTRACTOR: K.S. Sparks Standard 6" x 12 ", 28.27 square inches TICKET NO.: CONCRETE SUPPLIER: AMBIENT TEMP. (°F): PLANT/TRUCK: CONCRETE TEMP. ( °F) (ASTM C- 1064) MIX ID NUMBER: TIME BATCHED: AIR ( % ) (ASTM C -231) : TIME SAMPLED: WATER ADDED (gal): WEATHER CONDITION: SLUMP (in.) (ASTM C-143): LOCATION OF PLACEMENT: Sidewalk north CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) CMS 47 7 10 -11 -01 78700 2780 3000/28 days CMS 48 28 11 -01 -01 CMS 49 28 11 -01 -01 Specifications: Making & ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Fracture mode is (A) unless otherwise noted Types of Fracture: A® B C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician SMH /bg Distribution Shawn Wood FUGRO SOUTH INC. Reviewed By: K A Sparks Contractors Inc. — Jim Schooler K A Sparks Contractors Inc. — Jerry Jones (Fax: 972- 393 -1228) City of Coppell - Lee Stone City of Coppell - Garreth Campbell Coppell ISD - Mickey Harper SHW Group — Mike Elmore SHW Group — Dale Lilljedahl