Loading...
SC-Coppell MSW-LR011031FUGRO SOUTH, INC. �GRO 2880 Virgo Lane; Dallas, Texas 75229 Ph (972) 484 -8301; Fax (972) 620 -7328 COMPRESSIVE STRENGTH OF CONCRETE REPORT CLIENT Coppell ISD, c/o K A Sparks Report Date October 31, 2001 PROJECT Coppell Middle School West, Coppell, Texas Project No .: 0701 - 2192 SAMPLE DATE: October 4, 2001 CONTRACTOR: TICKET NO.: CONCRETE SUPPLIER: AMBIENT TEMP. ( °F): PLANT/TRUCK: CONCRETE TEMP. ( °F) (ASTM C- 1064): MIX ID NUMBER: TIME BATCHED: AIR ( % (ASTM C -231) : TIME SAMPLED: WATER ADDED (gal): WEATHER CONDITION: SLUMP (in.) (ASTM C -143) : LOCATION OF PLACEMENT: Kitchen slab CONCRETE CYLINDER COMPRESSIVE STRENGTH TESTS Standard 6" x 12 ", 28.27 square inches TOTAL COMPRESSIVE SPECIFIED COMPRESSIVE CYLINDER NUMBER AGE (days) DATE TESTED LOAD (pounds) STRENGTH (psi) STRENGTH (psi) CMS 50 7 10 -11 -01 122500 4330 3000/28 days CMS 51 28 11 -01 -01 160400 5670 CMS 52 28 11 -01 -01 162100 5730 CMS 53 Hold Fracture mode is (A) unless otherwise noted Specifications: Making & ASTM C -31 Curing: Testing ASTM C -143, Methods: ASTM C -39 Types of Fracture: A® B® C D REMARKS: Cylinders cast by Contractor. All information except test data furnished by Contractor and assumed to be correct. Technician: Shawn Wood FUGRO SOUTH INC. Reviewed By: SMH /rm Distribution: K A Sparks Contractors Inc. — Jim Schooler K A Sparks Contractors Inc. — Jerry Jones (Fax: 972 - 393 -1228) City of Coppell - Lee Stone City of Coppell - Garreth Campbell- Coppell ISD - Mickey Harper SHW Group — Mike Elmore SHW Group — Dale Lilljedahl