Country Estates-LR 921111Rose Engineers
Geotechnical Consultants
Materials Testing
RoneEngineers
r~~~.
Concrete Cylinder Test Report
Project Purchase Order
BETHEL
Number .. Date of Observation Report Date
D2-064A-O1-
ff
CITY OF C f
Location
SHOREWOOD +
Contractor
REBCON
Supplier Plant Truck Ticket
TXI
Mix Number Mix description
5273 5.5 SACK
Weather Conditions ~ AmbiecK Temperature (°~ Concrete Temperature (°~
CLEAR
tme Sampled Water Added
8 •-10 AM 0 . 0 GALS
Physical Data
ACTUAL ~ SPECIFICATIONS
SLUMP (in.) 4 1/2
Concrete Cylinder Test(s)
ACTUAL SPECIFICATIONS
Specimen Age Tot Load Compressive Strength Strength Required
No. (Days) I Test Date I lbs.) (ps) ~~
I I
66 .7 IO/16/92 I
76500 2710
3600
67 28 11/06/92 111500 3940
~68 28 11/06/92 122000 4320
69 HOLD HOLD
Curin Method
9 Test: Method Standard 6' x 17 Engineer echnician
ASTM C 31 ASTM C 39 Area 2627 sq. in. RANDY WORTHEN
Remarks and/or Distnbtrdon i
I
NATHAN D. MAIER/MIKE GARRETT (1), REBCON CONTRACTORS/
RICH BURCHETTE (1), CITY OF COPPELL/LARRY DAVI S (1)
~lione En sneers ,
UMRA7fONS• Tl+e test reautta Oresantrd Harem vrare pre0ared t>asad upon tlfe aoaerrle sarnpls orovda0 for tastlnq, We uwme no raoonsrourry sw
vanailon m puallly (comoosrtlon, appearance, peAOm+anca atcl or er~Y o0tar tsan+ra of similar woiaet maser provWed by psrson° or oonCttlo^s over `vhieh
as nsve no eantrol. Our latiera anq reports ara for tna eidutwe use o! tlia dlsnts to rrngn they an aotlroaseC,
Rone Engineers
Geotechnical Consultants
Materials Testing
RoneE ngine~ers
r
Concrete Cylinder Test Report
Prciect Purchase Order
BETHEL SCHOOL RD.
Numbef Date of Observation Report Date
D2-064A-O1-19512-B O
o -
CITY OF COPPELL
Location
SHOREWOOD @ STA: 4+50
Contractor
REBCON CONTRACTORS
Supplier Plant Truck Ticket
31 227
Mix Number Mix Description
8273
' Weather Conditions ~ Ambierrt Temperature (°~
( Concrete Temperature (°~
CLEAR I 78 75
tme Sampled Water Added -
2:15 PM 0 .0 GALS
Physical Data
ACTUAL ~ I SPECiFiCAT10NS
SLUMP (in.) 6 1/4
Concrete Cylinder Tests)
- ACTUAL SPECIFICATIONS
Specimen Age Tot Load Compressive Strength Strength Required
No. (Days) Test Date (lbs.) (pst) (Pstl
i
74 7 10/16/92 i
93000 3290
3600
75 28 11/06/92 112000 3960
-76 28 11/06/92 110000 3890
77 HOLD HOLD
Curing Method Test Method Standard 5 x 12' FsgineerfTechnician
ASTM c 3t ~ASTM C 39Area 2ez7 sq. in. i RANDY WORTHEN
Rensarks and for Distribution
NATHAN D. MAIER/MIKE GARRETT (1), REBCON CONTRACTORS/
RICH BURCHETTE (1), CITY OF COPPELL/LARRY DAVI S (1)
v,L
Rone sneers ,
UMRAT70NS: The test rewna presented Aere~n vrere txeoar<d ttased upon O+e apavfle farnt>tea t„a+daO for osatlnq. We aawm° no reaoonatbunY for
vanatbn m quallry icomooartfon, appearance, peAOrmar+ce, etcl or ar+v od+er feature of arm~lar wbieet matter povrded by persona or oondllJOro over whicA
we nsve no eonvoL Our Peden and retwro ua fa fns a:dusrvs use of Qfa dlana m v.Mm fnay w aooreasad. -
Rone Eng[neers
Geotechnical Consultants
Materials Testing
RoneEngin=
Concrete Cylinder Test Report
Purchase Order ~
Pro'ect
1 ~
BETHEL SCHOOL RD.
Number Date of Observation Report Date
D2-064A-O1-19545
CITY OF COPPELL
t_ocation
SHOREWOOD DRIVE @ STA: 2+00
Contractor "
REBCON CONTRACTORS
Supplier Plant Truck Ticket
TXI 31
Mix Number Mix Description
8273 5.5 SACK "
Weather Conditions (Ambient Temperature (°F7 Concrete Temperature {°~
CLEAR 68 7
tme Sampled Water Added
9:00 AM 0.0 GALS
Physical Data
ACTUAL - SPECIFICAT]ONS
SLUMP (in.') 4
Concrete Cylinder Test(s)
" ACTUAL SPECIFICATIONS
Specimen Age Tot Load Compressive Strength I Strength Required
No. (Days) Test Date (tbs.) (ps) ~~
~ i ~
78 7 10/19/92 79500 2810
3600
79 28 11/09/92 106000 3750
80 28 11/09/92 97000 3430 "
81 HOLD HOLD -
Curing Method Test Method Standard ~ x 12' Engineer/Technicaan
Cat ASTM C 39 Area 2sz7 sq. in. STEVE JOHNSTON CRONE
Remarks and/or Distnbution
NATHAN D. MAIER/MIKE GARRETT (1), REBCON CONTRACTORS/
RICH BURCHETTE (1), CITY OF COPPELL/LARRY DAVIS (1)
,~
' none Esiglneers
tJrYtrrgt)pNS: The test rewtts aeserNed Aarewt were OrteHed basso aeon [M soernre aernaee t>tovwea rer msarq. v.t uwme no resw....w.s •~^
venation m 4e+tay leomeosnion. aoPeerenoe. performance, etc) or e^f' oa+er fettur* d amWr wgect mteer powead try persorn a oonCltlone ovw v.hieh
r.e na.e no coned. Our isama anq reporn are for the esdusfve use d tM dleeo ID wean Grey an tatlresse4
Rone Engineers
Geotechnical Consultants
Materials Testing
RoneEngin®
r
Concrete Cylinder Test Report
Project Purchase Order
BETHEL SCHOOL '
Number Dale of Observation Report Date
D2-064A-O1-1954 -
CITY OF COPPELL
Location '
SHOREWOOD DRIVE STA:1+40
Contractor
REBCON CONTRACTORS
Supplier Plant Truck Ticket
TXI
Mix Number Mix Description
8273 5.5 SACK
weather Conditions ~ Ambient Temperature (°F) Concrete Temperature (°!7
CLEAR
ime Sampled Water Added
10:20 AM 0.0 GALS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4
Concrete Gyiinder Test(s)
ACTUAL SPECIFICATIONS
Specimen Age Tot Load Compressive Strength Strength Required
No. (Days) Test Date ~~) ~~ ~~
i t t i
82 .7 YO/19/92 94000 3330
3600
83 28 11/09/92 114000 4030
84 28 11/09/92 110000 3890
85 HOLD HOLD '
Curing Method Tess Method Standard 6' x t2' Engineer/Technician
ASTM C 37 ASTM C 39 Area 2&27 sq. in. STEVE JOHNSTON RONE
Remarks and/or Dis~bution
NATHAN D. MAIER/MIKE GARRETT (1), REBCON CONTRACTORS/
RICH BURCHETTE (1), CITY OF COPPELL/LARRY DAVIS (1)
I
~`~
Reno Fnntnware '
lJMrrAr70N3: 7Ae test rtwlb taresemed Aaron were t7rs'aara'4 based upon the soecifle sarnalee poridW tar tssgnq. We aswme ra rasaendbYMy for
ranaoon m QuaNty (ramooeroon, aooearanes, peAOnnancs. etel a arty other Faaturs W similar wbiect mottos arowo W by persons a pprtdlNOns orx r.hieh
as nave no control. Ow Naera arw reoorp are fp ate esdvsna use of afe dlano to venom they ors aedrwW,
Rone Engineers
Geotecttnical Consultants
Materials Testing
oo®gin
r
Concrete Cylinder Test Report
Project Purchase Order j
~
BETHEL SC OOL
Number Date of Observation Repoli Date
D2-064A-O1-198
o
CITY OF CO
Location
RETAINING WAL
Contractor
REBCON CONT C
Supplier PSant Truck Ticket
TXI
Mix Number Mix Description
8203
Weather Conditions ~ (Ambient Temperature (°F7 Concrete Temperature (°~
lme Sampled Water Added
12.10 PM 0.0 GALS
Physical Data
ACTUAL ~ I SPEC1FICATIONS
SLUMP (in.) 3 1/2
Concrete Cylinder Test(s)
• ACTUAL SPECIFICATIONS
Specimen Age Tot Load Compressive Strength Strength Required
No. (Days) Test Date pbs.) (ps) ~~~
i i
110 .7 11/10/92 91000 3220
3000
111 28 12/01/92
112 28 12/01/92
113 HOLD HOLD
Curing Method Test Method Standard 6' x 12• Engirxer/Technician
C 31 ASTM C 39 Area 2s.27 sq. in. BRIAN WILLIAMS
Remarks and/or Distribution
NATHAN D. MAIER/MIKE GARRETT (1), REBCON CONTRACTORS/ i
RICH BURCHETTE (1), CITY OF COPPELL/LARRY DAVIS (1)
r
~,~ ~-~^
~
nova Eriglneers ~
UMfTAT70N9: Ths test result pressmaO herein wa+e DreDaled b+sso u00a Ofa sOa01K samass OrOMOlC fOr dsonq, w! assume no rssvw~s~os~ iw
wnaVOn m quality (comoosmon, aoosarahee, performance. ere. or urY oa+ef f~aWn of nm~lar aubj°ct man°r provbed by p°eson° a oonaitlons ovx which
.we haul n0 COng01. Our IeQera and reooro era tp Via azdu4va use of 41a cllaho m wlfom Qfay an aOCnckC.