Loading...
Country Estates-LR 920830Rona Enstneers Geotechnical Consultants Materials Testing RoneEngin Concrete Cylinder Test Report Project Purchase Order COUNTRY ESTATES Number Date of Observation Report Date D2-211A-O1-18828 AUGUST 18, 1992 AUGUST 30, 1992 0 H.T. ARDINGER C/O NATHAN MAIER Location MAN-HOLE AT STA: 4+52 Contractor E.J. ALFORD 5uppfier Plant Trvck Ticket REDI-MIX 1 105 77547 Mix Number Mix Description 4200 Weather Conditions bient Temperature (°F~ Concrete Temperature (°F~ OVERCAST/DRIZZLE 85 85 tme Sampled Water Added 1:40 PM 0.0 GALS Physical Data ACTUAL ~ ~ SPECIFICATIONS SLUMP (in.) 1/2 Concrete Cylinder Test(s) ACTUAL SPECIFICATIONS Specimen Age Tesf Date Tot Load Compressive Strength Strengtfi Required No. (Days (fbs.) ~, ~? i i 1 7 08/25/92 140000 4950 4000 2 28 09/15/92 3 28 09/15/92 Curing Method Test Method Standard 6' x 12' E.ngineer/Technician ASTM C 31 ASTM C 39 Area 213.27 sq. in. STEVE JOHNSTON CRONE) Remarks and/or Distribution H.T. ARDINGER C/O NATHAN MAIER/MIKE GARRETT (1), NATHAN D. MAIER/ MIKE GARRETT (1), CITY OF COPPELL/LARRY DAVIS (1), E.J. ALFORD/ (1), H.C.H. CONSTRUCTION/JEFF HICKS (1) i'1~,1 f ~Q~ C~ _ ~ . UMRATiONS: 7ha lest rawRS presented herein vrere prepared fused upon the speCiflC samples provided ~ tntlng. We assume M Oo 6UIty for Wane cngrnesrs vanafbn m Qvdlty (eomposroorf, aptxsranee, prnlormanc°, etc) or ~rry oCrer fse+ure d xmily s°bpci matter poviCed py persona oar rp+Mitlons over whictr we have M convot. Our IeCer7 anal report ars for the etWUSlvs use of tAs Ulenn ID vrhpm tn~, e~ eyed. _