Loading...
Coppell Trade 2-LR061014F~ _ U. FARGO CONSULTANTS, INC 11440 Reeder Rd. Dallas, 'T'exas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Cornmerc>al Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 10/14/06 Project No: M06-1165 Location: Bulldmg pad, eastern '/2 - 2° pass Area injected previously: Approximately 14,200 square feet of 2nd pass Area injected (on this day): Approximately 9,200 square feet of 2nd pass Area injected (to date): Approximately 23,400 square feet of 2nd pass Gallons of Water used: 50,400 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks: Time Start 7 00 a.m. End 2 45 p.m. Technician. Joshua Solon Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller- Jon Jacobson City ofCoppell -Lee Stone Specified Requirements as per manufacturer 50 psi-100pst 5 feet (max.) 12 inches 12 feet Water Meter Reading 7703900 7753300 Checked by LIMITATIONS. This report presents test results (at particular locations noted) based ou data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality performance, feature or conditions beyond its control. 'This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Ceotechnical Engineering Construction Materials Testing Environmental Services www dallasfargo com