Coppell Trade 2-LR061013i FARGO CONS17ZTAN~TS, INC. WATER PRESSURE INJECTION OBSERVATION REPORT Client; Holt Lunsford Cotnmercr<al Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: McFadder Miller 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 Date of Service: 10/13/06 Project No: M06-1165 Location: Bu>ld>ng, east %2 - 2° pass Area injected previously: Approximately 7,000 square feet of 2°d pass Area injected (on this day): Approximately 7,200 square feet of 2°d pass Area injected (to date): Approximately 14,200 square feet of 2°d pass Gallons of Water used: 45,500 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks: Time Start 8 00 a.m. / 1.00 p.m. End 10.00 p.m. / 3.00 p.m. Technician Joshua Solon Specified Requirements as per manufacturer 50 psi-100psi 5 feet (max.) 121nches 12 feet Water Meter Reading 7,657,400 7,702,900 Distribution Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone Checked by LIMITATIONS. This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) [o whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnica! Engineering Construction Materials Testing Environmental Services www.dallasfargo com