Coppell Trade 2-LR061013i
FARGO CONS17ZTAN~TS, INC.
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client; Holt Lunsford Cotnmercr<al
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: McFadder Miller
11440 Reeder Rd. Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Page 1 of 1
Date of Service: 10/13/06
Project No: M06-1165
Location: Bu>ld>ng, east %2 - 2° pass
Area injected previously: Approximately 7,000 square feet of 2°d pass
Area injected (on this day): Approximately 7,200 square feet of 2°d pass
Area injected (to date): Approximately 14,200 square feet of 2°d pass
Gallons of Water used: 45,500
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 100
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks:
Time
Start 8 00 a.m. / 1.00 p.m.
End 10.00 p.m. / 3.00 p.m.
Technician Joshua Solon
Specified Requirements
as per manufacturer
50 psi-100psi
5 feet (max.)
121nches
12 feet
Water Meter Reading
7,657,400
7,702,900
Distribution Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
Checked by
LIMITATIONS. This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no
responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) [o whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, Inc.