Coppell Trade 2-LR061019/ ! ~~/.
FARGO CONSULTANTS, INC.
11440 Reeder Rd. • Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Pagelofl
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commercial
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden & Miller
Date of Service: 10/19/06
Project No: M06-1165
Location: Building D east half - 2n pass
Area injected previously: Approximately 43,700 square feet of 2nd pass
Area injected (on this day): Approximately 12,000 square feet of 2nd pass
Area injected (to date): Approximately 55,700 square feet of 2nd pass
Gallons of Water used: 56,000
Surfactant Used: /gallon / 3,500 gallons of water
Injection Pressure (psi): 100
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks:
Time
Start 9:00 a.m. / 2 p.m.
End 11:50 a.m. / 3:00 p.m.
Specified Requirements
as per manufacturer
50 psi-100psi
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7904500
7960500
Technician: Joshua Solon
Distribution: Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
,~
Checked by: `~
LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. asswnes no
responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, lnc.
Geotechnical Engineering • Construction Materials Testing • Environmental Services
www. dallasfargo. com
~~o.
FARGO CONSLJLTAN'.PS, INC.
11440 Reeder Rd. Dallas, Texas 7229
Tel. 214-352-4100 Fax. 214-352-4811
Pagelofl
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client :Holt Lunsford Commercial
Project: Coppell Trade Center Buildutg D
Coppell, Texas
Injection Contractor: Mcfadden & Miller
Date of Service: 10/09/06
Project No: M06-1165
Location: Building pad, north portion of east half
Area injected previously: Approximately 31,280 square feet of 1St pass
Area injected (on this day): Approximately 8,300 square feet of 1St pass
Area injected (to date): Approximately 39,580 square feet of 1St pass
Gallons of Water used: 43,200
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 100
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks
Time
Start 7.00 a.m.
End 3.00 p.m.
Technician. Joshua Solon
Distribution Holt Lansford Commercial -Ken Newman
Mcfadden & Miller-Jon Jacobson
City of Coppell -Lee Stone
Specified Reauirements
as per manufacturer
50 psi-200psi
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7,504,700
7,547,900
Checked by
LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected For testing. Fargo Consultants, Inc. assumes no