Loading...
Coppell Trade 2-LR061019/ ! ~~/. FARGO CONSULTANTS, INC. 11440 Reeder Rd. • Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Pagelofl WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 10/19/06 Project No: M06-1165 Location: Building D east half - 2n pass Area injected previously: Approximately 43,700 square feet of 2nd pass Area injected (on this day): Approximately 12,000 square feet of 2nd pass Area injected (to date): Approximately 55,700 square feet of 2nd pass Gallons of Water used: 56,000 Surfactant Used: /gallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks: Time Start 9:00 a.m. / 2 p.m. End 11:50 a.m. / 3:00 p.m. Specified Requirements as per manufacturer 50 psi-100psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 7904500 7960500 Technician: Joshua Solon Distribution: Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone ,~ Checked by: `~ LIMITATIONS: This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. asswnes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, lnc. Geotechnical Engineering • Construction Materials Testing • Environmental Services www. dallasfargo. com ~~o. FARGO CONSLJLTAN'.PS, INC. 11440 Reeder Rd. Dallas, Texas 7229 Tel. 214-352-4100 Fax. 214-352-4811 Pagelofl WATER PRESSURE INJECTION OBSERVATION REPORT Client :Holt Lunsford Commercial Project: Coppell Trade Center Buildutg D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 10/09/06 Project No: M06-1165 Location: Building pad, north portion of east half Area injected previously: Approximately 31,280 square feet of 1St pass Area injected (on this day): Approximately 8,300 square feet of 1St pass Area injected (to date): Approximately 39,580 square feet of 1St pass Gallons of Water used: 43,200 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks Time Start 7.00 a.m. End 3.00 p.m. Technician. Joshua Solon Distribution Holt Lansford Commercial -Ken Newman Mcfadden & Miller-Jon Jacobson City of Coppell -Lee Stone Specified Reauirements as per manufacturer 50 psi-200psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 7,504,700 7,547,900 Checked by LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected For testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) [o whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering Construction Materials Testing Environmental Services tvww.dallasfargo coin