Coppell Trade 2-LR061006~~ GO. FARGO CONSUI~TAN~TS, INC 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & Miller Date of Service: 10/06/06 Project No: M06-1165 Location: Building pad -east half -working south to north Area injected previously: Approxtmately 22,680 square feet of 1St pass Area injected (on this day): Approxtmately 8,600 square feet of 1St pass Area injected (to date): Approximately 31,280 square feet of 1St pass Gallons of Water used: 49,300 Surfactant Used: /gallon / 3,500 gallons of water Injection Pressure (psi): 125 average Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks. Time Start 7'00 a.m. End 2 49 p.m. Technician. Joshua Solon Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone Specified Requirements as per manufacturer 50 pst-200ps> 5 feet (max.) 12 inches 12 feet Water Meter Reading 7,455,400 7,504,700 Checked by LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assmmes no responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, hic. Geotechnical Engineering Construction Materials Testing Environmental Services www.clallasfargo com