Coppell Trade 2-LR061006~~ GO.
FARGO CONSUI~TAN~TS, INC
11440 Reeder Rd. Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Page 1 of 1
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commercial
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden & Miller
Date of Service: 10/06/06
Project No: M06-1165
Location: Building pad -east half -working south to north
Area injected previously: Approxtmately 22,680 square feet of 1St pass
Area injected (on this day): Approxtmately 8,600 square feet of 1St pass
Area injected (to date): Approximately 31,280 square feet of 1St pass
Gallons of Water used: 49,300
Surfactant Used: /gallon / 3,500 gallons of water
Injection Pressure (psi): 125 average
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks.
Time
Start 7'00 a.m.
End 2 49 p.m.
Technician. Joshua Solon
Distribution. Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
Specified Requirements
as per manufacturer
50 pst-200ps>
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7,455,400
7,504,700
Checked by
LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assmmes no
responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, hic.