Loading...
Coppell Trade 2-LR061005AGO rARGU CONSULTANTS, INC 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & M111er Date of Service: 10/OS/06 Project No: M06-1165 Location: Building pad, '/ of east buildtng Area injected previously: Approximately 22,680 square feet of 1St pass Area injected (on this day): Approximately 6,500 square feet of 1St pass Area injected (to date): Approximately 29, 180 square feet of 1St pass Gallons of Water used: 31,600 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 100 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks. Time Start 8 a.m. / 1 p.m. End 10 a.m. / 3 p.m. Specified Requirements as per manufacturer 50 psi-200ps1 5 feet (max.) 12 inches 12 feet Water Meter Reading 7423800/- -/7455400 Technician. Moe Mumm Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller-Jon Jacobson City of Coppell -Lee Stone Checked by UM]TATfONS. This report presents test results (a[ particular locations noted) based on data obtained from specific samples selected for testing. Fargo Co~uultants, (nc. assumes no responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc. Geotechnical Engineering Construction Materials Testing Environmental Services www dallasfargo com