rARGU CONSULTANTS, INC
11440 Reeder Rd. Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Page 1 of 1
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commercial
Project: Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden & M111er
Date of Service: 10/OS/06
Project No: M06-1165
Location: Building pad, '/ of east buildtng
Area injected previously: Approximately 22,680 square feet of 1St pass
Area injected (on this day): Approximately 6,500 square feet of 1St pass
Area injected (to date): Approximately 29, 180 square feet of 1St pass
Gallons of Water used: 31,600
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 100
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks.
Time
Start 8 a.m. / 1 p.m.
End 10 a.m. / 3 p.m.
Specified Requirements
as per manufacturer
50 psi-200ps1
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7423800/-
-/7455400
Technician. Moe Mumm
Distribution. Holt Lansford Commercial -Ken Newman
Mcfadden & Miller-Jon Jacobson
City of Coppell -Lee Stone
Checked by
UM]TATfONS. This report presents test results (a[ particular locations noted) based on data obtained from specific samples selected for testing. Fargo Co~uultants, (nc. assumes no
responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, Inc.