Coppell Trade 2-LR061004FGU ~~
FAKGO CONSUT,TANTS, INC
11440 Reeder Rd. Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Page 1 of 1
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Cotnmerctal
Project: Coppell Trade Center Bui1dIllg D
Coppell, Texas
Injection Contractor: Mcfadden & M111er
Date of Service: 10/04/06
Project No: M06-1165
Location: Building pad-middle portion of eastern half
Area injected previously: Approxlmately 16,180 square feet of 1St pass
Area injected (on this day): Approximately 6,500 square feet of 1St pass
Area injected (to date): Approx>mately 22, 680 square feet of 1St pass
Gallons of Water used: 66,000
Surfactant Used: /gallon / 3,500 gallons of water
Injection Pressure (psi): 150
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: 12-18
Total Depth of Injection (feet): 12
Remarks.
Time
Start 7 00 a.m.
End 3.00 p.m.
Technlcian. Joshua Solon
Distribution. Holt Lansford Commercial -Ken Newman
Mcfadden & Miller -Jon Jacobson
City of Coppell -Lee Stone
Specified Reauirements
as per manufacturer
50 psi-200psi
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7,357,800
7,423,800
Checked by
LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no
responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, Inc,
Geotechnical Engineering Constrcrction Materials Testing Environmental Services