Loading...
Coppell Trade 2-LR061004FGU ~~ FAKGO CONSUT,TANTS, INC 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Cotnmerctal Project: Coppell Trade Center Bui1dIllg D Coppell, Texas Injection Contractor: Mcfadden & M111er Date of Service: 10/04/06 Project No: M06-1165 Location: Building pad-middle portion of eastern half Area injected previously: Approxlmately 16,180 square feet of 1St pass Area injected (on this day): Approximately 6,500 square feet of 1St pass Area injected (to date): Approx>mately 22, 680 square feet of 1St pass Gallons of Water used: 66,000 Surfactant Used: /gallon / 3,500 gallons of water Injection Pressure (psi): 150 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks. Time Start 7 00 a.m. End 3.00 p.m. Technlcian. Joshua Solon Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppell -Lee Stone Specified Reauirements as per manufacturer 50 psi-200psi 5 feet (max.) 12 inches 12 feet Water Meter Reading 7,357,800 7,423,800 Checked by LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, Inc. assumes no responsibility for variation in quality, performance, feature or conditions beyond its control. This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, Inc, Geotechnical Engineering Constrcrction Materials Testing Environmental Services www.dallasfargo coin