Loading...
Coppell Trade 2-LR061003!'/'/ / V r'ARGO CONSI7LTANTS, INC. 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Page 1 of 1 WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commercial Project: Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden & M111er Location: Bu11d1ng pad, South portlon of east half Area injected previously: Approximately 8,020 square feet of 1 St pass Area injected (on this day): Approxlmately 8,160 square feet of 1St pass Area injected (to date): Approximately 16, 180 square feet of 1St pass Gallons of Water used: 57,400 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 150 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: 12-18 Total Depth of Injection (feet): 12 Remarks: Time Start 7 15 a.m. End 3.04 p.m. Technician. Joshua Solon Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller -Jon Jacobson City of Coppel] -Lee Stone Date of Service: 10/03/06 Project No: M06-1165 Specified Requirements as per manufacturer 50 ps1-200ps1 5 feet (max.) 12 inches 12 feet Water Meter Reading 7,300,400 7,357,800 Checked by L1M(TATIONS. This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, hic. assumes no responsibility for variation in quality performance, feature or conditions beyond its control. This report is for the exclusive use of Hie person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Corsultants, Inc. Geotechnical Engineering Consh-trction Materials Testing Environmental Services www dallasfargo coin