Coppell Trade 2-LR061002F ~O
FAKGO CONSL77,'CANT S, INC.
11440 Reeder Rd. Dallas, Texas 75229
Tel. 214-352-4100 Fax. 214-352-4811
Pagelofl
WATER PRESSURE INJECTION
OBSERVATION REPORT
Client: Holt Lunsford Commerctal
Project; Coppell Trade Center Building D
Coppell, Texas
Injection Contractor: Mcfadden and Miller
Date of Service: 10/02/06
Project No: M06-1165
Location: Building pad-East half
Area injected previously: 0 sq ft.
Area injected (on this day): Approximately 8,020 square feet of 1st pass
Area injected (to date): Approxtmately 8,020 square feet of 1St pass
Gallons of Water used: 47,300
Surfactant Used: lgallon / 3,500 gallons of water
Injection Pressure (psi): 150
Injection Probe Spacing (feet): 5
Injected Depth Interval (in.) until refusal: N/A
Total Depth of Injection (feet): 12
Remarks:
Time
Start 9.00 a.m.
End 3.20 p.m.
Technician. Joshua Solon
Distribution. Holt Lansford Commercial -Ken Newman
Mcfadden & Miller- Jon Jacobson
City of Coppel] -Lee Stone
Specified Requirements
as per manufacturer
50 psi-200ps1
5 feet (max.)
12 inches
12 feet
Water Meter Reading
7,253,100
7,300,400
Checked by
LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, htc. assumes no
responsibility for variation in quality performance, feature or conditions beyond its control This report is for the exclusive use of the person(s) to whom it is addressed
and may not be reproduced except in full without the written approval of Fargo Consultants, ]nc.