Loading...
Coppell Trade 2-LR061002F ~O FAKGO CONSL77,'CANT S, INC. 11440 Reeder Rd. Dallas, Texas 75229 Tel. 214-352-4100 Fax. 214-352-4811 Pagelofl WATER PRESSURE INJECTION OBSERVATION REPORT Client: Holt Lunsford Commerctal Project; Coppell Trade Center Building D Coppell, Texas Injection Contractor: Mcfadden and Miller Date of Service: 10/02/06 Project No: M06-1165 Location: Building pad-East half Area injected previously: 0 sq ft. Area injected (on this day): Approximately 8,020 square feet of 1st pass Area injected (to date): Approxtmately 8,020 square feet of 1St pass Gallons of Water used: 47,300 Surfactant Used: lgallon / 3,500 gallons of water Injection Pressure (psi): 150 Injection Probe Spacing (feet): 5 Injected Depth Interval (in.) until refusal: N/A Total Depth of Injection (feet): 12 Remarks: Time Start 9.00 a.m. End 3.20 p.m. Technician. Joshua Solon Distribution. Holt Lansford Commercial -Ken Newman Mcfadden & Miller- Jon Jacobson City of Coppel] -Lee Stone Specified Requirements as per manufacturer 50 psi-200ps1 5 feet (max.) 12 inches 12 feet Water Meter Reading 7,253,100 7,300,400 Checked by LIMITATIONS This report presents test results (at particular locations noted) based on data obtained from specific samples selected for testing. Fargo Consultants, htc. assumes no responsibility for variation in quality performance, feature or conditions beyond its control This report is for the exclusive use of the person(s) to whom it is addressed and may not be reproduced except in full without the written approval of Fargo Consultants, ]nc. Geotechnical Engineering Construction Materials Testing Environmental Services www.dallasfargo com