ST9902-LR061102 Concrete Compression Test Report eM J ENGINEERING, INC. . 7636 Pebble Drive Fort Worth, Texas 76118 Tel: (8 84-9400 Fax: (817) 589-9993 Report Distribution: (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins Client: Project: City of Coppell West Sandy Lake R Reconstruction CMJ Report No.: 687-5192-164 Report Date: 11/22/2006 Strength Slump Air Content Concrete Temperature Ambient Temperature Specifications Test Data 3500 psi @ 28 Days 4 in max 3 % min 6 % max n/a 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method 10/23/2006 Contractor Made n/a N/AlN/A Ticket Number: Slump: Concrete Temperature: Placement Location: Sample Location: n/a n/a Time Batched: n/a n/a Air Content: n/a n/a Ambient Temperature: n/a Stamped Concrete Sidewalk Time Sampled: n/a Unit Weight: n/a Yardage (c.y.): n/a Concrete Compression Test Results Cylinder Age Max Load Area Stren8th Fracture Set # # Test Date (days) (Ibs. force) (sq.in.) (pSI Type 01 SLR10230601 1 0/30/2006 7 77520 27.90 2780 C-cone/shear 01 SLR10230602 11/20/2006 28 122360 27.99 4370 B-cone/split 01 SLR10230603 11/20/2006 28 118520 27.99 4230 B-cone/split 01 SLR10230604 Hold 28 day average 4300 Normal cylinder size: 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. *ALL INFORMATION PROVIDED BY CONTRACTOR r,/~ /I- z1' ~~ / LIMITATIONS: The test results presented in this report apply only to the specific samples, items, and Jeas described within this report. The test results do not pertain to any other samples, items or areas regardless of similarity. Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. 01 CMJ Engineering, 'nc R. Carl ~ e, SET. Vice PresidentlCMT Manager Page I of I eM J ENGINEERING, INC 7636 Pebble Drive Fort Worth, Texas 76118 Tel (817) 284-9400 Fax: (817) 589-9993 Concrete Compression Test Report Client: Project: City of Cappel! West Sandy Lake Road Reconstruction Report Distribution (1) City of Coppell (1) City of Coppell (1) Tiseo Paving Company (1) Teague Nail & Perkins CMJ Report No. Report Date 687-5192-164 11/02/2006 Strength Slump Air Content Specifications 3500 psi @ 28 Days 4 in max 3 % min 6 % max n/a Test Data Concrete Temperature Ambient Temperature 400 F min Placement Date Sampled By Weather Supplier/Mix Air Content Method 1 0/23/2006 Contractor Made n/a N/ A/N/ A Ticket Number' Slump Concrete Temperature Placement Location n/a Time Satched n/a n/a Air Content: n/a n/a Ambient Temperature n/a Stamped Concrete Sidewalk Time Sampled. n/a Unit Weight: n/a Yardage (c.y). n/a Sample Location n/a Concrete Compression Test Results Cylinder Age Max Load Area Set# # Test Date (days) (Ibs force) (sq.in.) 01 SLR 10230601 10/30/2006 7 77520 2790 01 SLR10230602 11/20/2006 28 01 SLR10230603 11/20/2006 28 01 SLR10230604 Hold Strength (psi) 2780 Fracture Type C-cone/shear Normal cylinder size, 6" x 12" Field and laboratory tests by CMJ are per applicable ASTM Standards, C31, C39, C138, C143, C172, C1064, and C617 or C1231 *ALL INFORMATION PROVIDED BY CONTRACTOR CMJ Engineering, Inc LIMITATIONS The test results presented in this report apply only to the specific samples, items, and areas described within this report, The test results do not pertain to any other samples, items or areas regardless of similarity Our reports are produced solely for the exclusive use of our client. This report or any portion of this report may not be reproduced without the written consent of our client and CMJ Engineering, Inc. "I Page I of I