Loading...
PA9901-LR061101LAWRENCE ENGINEERING I• ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -010 Report Date: 11/0112006 Specifi Cylinder Test Data Strength 3600 psi @ 28 Days Placement Date 10/26/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cool /Sunny Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C-231 -B Ticket Number: 350810 Time Batched: 8:00 AM Time Sampled: 8:40 AM Slump: 4 in Air Content: 3.9% Unit Weight: Concrete Temperature: 79° F Ambient Temperature: 78° F Yardage (c.y.): 10 of 140 Placement Location: Paving 10' E. of TC 20.93 Sample Location: Co�Co�p�essi�mT Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. W Page I of 2 Cylinder A Max Load Area Streength Fr a cture Set # # Test Date t (days (lbs. force (sq.in. ) )) Typ 1 WWP10260601 11/02/2006 7 105830 28.27 3740 unbonded cap 1 WWP10260602 11/23/2006 28 1 W W P 10260603 11/23/2006 28 1 WWP10260604 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. W Page I of 2 LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -010 Report Date: 11101/2006 Specifications Test Data Strength 3600 psi @ 28 Days Placement Date 10/26/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cool /Sunny Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C -231 -8 FiieW, f cats . Ticket Number: 350954 Time Batched: 9:35 AM Time Sampled: 10:25 AM Slump: 5 in Air Content: 4.5% Unit Weight: Concrete Temperature: 81' F Ambient Temperature: 80° F Yardage (c.y.): 120 of 150 Placement Location: Paving 15'N. of TC 20.50 Sample Location: Concrsete' Cylinder Age Max Load Area Stren th Fracture Set # # Test Date (days) (Ibs, force) (sq.in.) (psi Type 2 WWP10260605 11/02/2006 7 111660 28.27 3950 unbonded cap 2 W W P 10260606 11/23/2006 28 2 WWP10260607 11/23/2006 28 2 WWP10260608 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. f i LAWRENCE ENGINEERING F Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. Page 2 of 2 of LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite S Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -011 Report Date: 11/01/2006 Specifications Cylinder # Test Data Strength 3600 psi @ 28 Days Placement Date 10/27/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cold/Windy Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C-231 -B Field' Data Set #1 Ticket Number: 351543 Time Batched: 7:18 AM Time Sampled: 8:00 AM Slump: 5 in Air Content: 4.4% Unit Weight: Concrete Temperature: 76° F Ambient Temperature: 52° F Yardage (c.y.): 30 of 100 Placement Location: 25'W. of TC 20.66 from grading plan L -3 Sample Location: Concrete Compression Tes€;F Set # Cylinder # Test Date Age Max Load Area Stren th Fracture (days) (lbs. force) (sq.in.) (psl� Type 1 WWP10270601 11/03/2006 7 120970 28.27 4280 unbonded cap 1 WWP10270602 11/24/2006 28 1 WWP10270603 11/24/2006 28 1 WWP10270604 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 l LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. 01 Pagel of 2 LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite S Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 11MIIIIII Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -011 Report Date: 11/01/2006 Specifications Cylinder # Test Data Strength 3600 psi @ 28 Days Placement Date 10/27/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cold/Windy Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C -231 -13 Field-Data Set #2 - Ticket Number: 357782 Time Batched: 9:54 AM Time Sampled: 10:35 AM Slump: 4.5 in Air Content: 3.9% Unit Weight: Concrete Temperature: 74° F Ambient Temperature: 52° F Yardage (c.y.): 108.5 of 108 Placement Location: 5'S. of TC 18.80 from grading plan L -3 Sample Location: Concrete Compression T R"Atst Set# Cylinder # Test Date Age Max Load Area Stren th Fracture (days) (lbs. force) (sq.in.) (ps11 Type 2 WWP10270605 11/03/2006 7 123360 28.27 4360 unbonded cap 2 W W P 10270606 11/24/2006 28 2 WWP10270607 11/24/2006 28 2 WWP10270608 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. of Page 2 of 2 LAWRENCE ENGINEERING I♦ ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 I• Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -013 Report Date: 11/01/2006 Speci Tes Data Strength 3600 psi @ 28 Days Placement Date 10/30/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cool/Windy Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C -231 -B Ticket Number: 352789 Time Batched: 6:51 AM Time Sampled: 7:35 AM Slump: 4.5 in Air Content: 4.9% Unit Weight: Concrete Temperature: 76° F Ambient Temperature: 60° F Yardage (c.y.): 20 of 250 Placement Location: Paving 10'N of TC 20.40 (Grading plan L -3 Sample Location: Gonc>r�ate,�Cori+o�- 'Ee�srj :., ; Cylinder Age Max Load Area Stren th Fracture Set # # Test Date (days) (lbs. force) (sq.in.) (psi Type 1 WWP10300601 11/06/2006 7 99840 28.27 3530 unbonded cap 1 WWP10300602 11127/2006 28 1 WWP10300603 11/27/2006 28 1 WWP10300604 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231. LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. 0 Page 1 of 2 LAWRENCE ENGINEERING _ ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Concrete Compression Test Report Client: City of Coppell Report Distribution: (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No.: C06- 0903 -013 Report Date: 11/01/2006 Specifications Cylinder # Test Da Strength 3600 psi @ 28 Days Placement Date 10/30/2006 Slump 3 in min 5 in max Sampled By Joe Flores Air Content 3 % min 6 % max Weather Cool/Windy Concrete Temperature 95° F max Supplier /Mix TXI/8274 Ambient Temperature n/a Air Content Method ASTM C -231 -B Field Dial Set 2 Ticket Number: 352991 Time Batched: 9:05 AM Time Sampled: 10:00 AM Slump: 5 in Air Content: 4.2% Unit Weight: Concrete Temperature: 76° F Ambient Temperature: 68° F Yardage (c.y.): 120 of 250 Placement Location: Paving 5' E. of TC 17.94 (Grading plan L -3 Sample Location: Set # Cylinder # Test Date Age Max Load Area (days) (lbs. force) (sq.in.) Stren th Fracture (psi? Type 2 WWP10300605 11/06/2006 7 113850 28.27 4030 unbonded cap 2 WWP10300606 11/27/2006 28 2 WWP10300607 11/27/2006 28 2 WWP10300608 Hold Normal cylinder size: 6" x 12" Field and laboratory tests by LE are per applicable ASTM Standards: C31, C39, C138, C143, C172, C1064, and C617 or C1231 LAWRENCE ENGINEERING Gary D. Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein. is strictly prohibited without the express written consent of LE. C1 Page 2 of 2 LAWRENCE ENGINEERING _ ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Moisture - Density Relationship Client: City of Coppell Report Distribution (1) Larry Davis - City of Coppell Project: Wagon Wh I Park (1) John Elias - Parks Dept. Parking L Improvements TMI Report No. C06- 0903 -005 Report Date 11/01/2006 Project Information Material Origin On -Site Tested By Ozzie Flores Sample Location 80'S X 125'W of Northside Inlet Sample Date 10/11/0206 Material Description Limetreated Dark Brown Clay w/ Gravel Material Use Sub -Grade Moisture - Density Relationship - Curve No. 686 95 93 Dry Density (pcf) 91 89 87 100% Saturation 21 23 25 27 29 31 33 Moisture Content ( %) Material Properties and Test Information - Curve No. 686 Maximum Dry Density- F Optimum Moisture Percent: Test Method(s) ASTM D -698 -A Rammer Description Mechanical Preparation Procedure Moist l i t e x "! LAWRENCE ENGINEERING Gary D Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein is strictly prohibited without the express written consent of LE "6 Pate I of 1 LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Report of Cancellation of Services Client: City of Coppell Report Distribution (1) Larry Davis - City of Coppeil Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No. C06- 0903 -009 Report Date. 11/01/2006 On Ooctober 25, 2006, Joe Flores of Lawrence Engineering was on location at the above referenced project to perform concrete placement. Upon on arrival technician was informed that this day's activity had been cancelled and will rescheduled for a later date Y -�� Z. LAWRENCE ENGINEERING Ga D Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested. This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. Paget of I 99 LAWRENCE ENGINEERING ENVIRONMENTAL - GEOTECHNICAL - CONSTRUCTION MATERIALS TESTING 12500 Schroeder Suite B Dallas, Texas 75243 Phone (972) 497 -9100 Fax (972) 497 -9108 Report of Cylinder /Beam Collection Client: City of Coppell Report Distribution (1) Larry Davis - City of Coppell Project: Wagon Wheel Park (1) John Elias - Parks Dept. Parking Lot Improvements LE Report No. C06- 0903 -012 Report Date. 11101/2006 Cylinder Collection On October 28, 2006, Joe Flores of Lawrence Engineering was on location at the above referenced project to perform cylinder collection of concrete test cylinders cast on October 27, 2006 2 sets of 4 cylinders each were collected and transported to laboratory LAWRENCE ENGINEERING GAry D Dry Construction Materials Manager The results presented in this report pertain only to the specific items tested This report was produced for the exclusive use of the client. Any reproduction of this report, or any part therein, is strictly prohibited without the express written consent of LE. Page l of 1 )9