Gateway BP(1.6)-LR061106CONCRETE COMPRESSIVE STRENGTH TEST l~~rr~con
Report Number: 94061163.0132
8901 Carpenter Frwy, Ste #100
Service Date: October 23, 2006 Dallas, Texas 75247
{214)630-1010
Client: Report Date: November 06, 2006
ProLogis Project: Freeport Corporate Ctr. Bldg. 6
Attn: Keith Porter Freeport Pkwy & Gateway
2310 LBJ Freeway Ste 200 Coppell, TX
Dalian TX 75234
Project No.: 94061163
Material Information
Specified Strength: 3000 psi @ 28 Days
Batch Time: 2:36 PM Plant; 27
Supplier: Southern Star Concrete
Truck No: 1883 Ticket No: 1449023
Mix I.D. No.: 9337
Water Added Onsite Before Test: 6Gallons
Water Added Onsite After Test: 0 Gallons
Field Test Dafa
Test Result
Slump, inches: 4.75
Air Content, %: 3.6
Concrete Temperature, oF: 7g
Ambient Temperature,~F: 75
Plastic Unit Weight, pcf: N/A
Sample Information
Date Cast: October 23, 2006 Time: 3:24 PM
Sampled by: Ira S. Haynes
Weather Conditions: Clear, windy
Accumulative Yards: 10/10
Placement Method: Direct Discharge
Sample Locations: SW Dock Entrance Walls
Placement Location: Ramp Walls for Dock Entrance
Specification Test Method
3-5 ASTM C143
3-6 ASTM C231
ASTM C1064
ASTM C1064
ASTM C138
Laborato ry Test Data
Age at Maximum Compressive
Set Spe cimen Diameter Area Date Test Load Strength
No. ID (inches) (sq. inches) Tested days) (Ibs) (psi)
1 1 6.00 28.27 10/30/2006 7 89, 960 3,180
1 2 11 /20/2006 28
1 3 11/20/2006 28
1 4 12/18/2006 56
Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive
strength samples.
Terracon Rep: Ira S. Haynes
Report Distribution:
(1) ProLogis (1) Meinhardt & Assoc Architects PLLC
(1) City of Coppell TX (1) Jordan Gonstruction Services Reviewed by:
(1) City of Coppell TX (1) Meinhardt 8 Assoc Architects PLLC Robert D. Ra S.
(1) Haynes Whaley Assoc Inc Y.
Senior Project Hager
The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client
indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable
to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical
materials.
Page 1 of 1 ~, Po~o,f~~e k.Y