ST9302-LR 991208A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
DATE OF ISSUE
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO
COPPELL, TEXAS
I2 1-- Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractor's representative.
ICS Cylinders picked up by ALPHA
laboratory.
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 49 +00
DATE PLACED
10/22/99
TIME
17:15
SLUMP (ASTM C -143)
3
AIR CONTENT (ASTM C -231 ❑ OR C -173 14r
4.75
AIR TEMPERATURE
89
CONCRETE TEMPERATURE
93
DATE RECEIVED
10/25/99
FIELD DATA SUBMITTED BY
KALU
MIX DATA SUBMITTED BY
TXI
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 0
PLANT
N/A
DELIVER TICKET NO.
20301
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C -39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
94
LAB
10/29/99
7
101,545
28.27
3,590
95
LAB
11/19/99
28
121,631
28.27
4,300
96
LAB
11/19/99
28
120,322
28.27
4,260
97
LAB
HOLD
H
28.27
I Speclifications 28
1 3,500
REMARKS
REPORT OF CONCRETE
COMPRESSION TEST
❑ Cylinders delivered to ALPHA
laboratory.
pression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
10/22/99
(REVISED 12/8/99)
98881 -100
Res 7HATEST ly Submitted
AL
Geotechnical Engineering ■ Construcfion Materials Testing ■ Environmental Engineering ■ Consulfing
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620 -8911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
REPORT OF CONCRETE
COMPRESSION TEST
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE
OUR REPORT NO
13--,Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
�,� or Contractor's representative.
[? picked up by ALPHA
laboratory.
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 45 +50
DATE PLACED
10/25/99
TIME
10:15
SLUMP (ASTM C -143)
2
AIR CONTENT (ASTM C -231 ❑ OR C -173 2F'
4.25
AIR TEMPERATURE
72
CONCRETE TEMPERATURE
74
DATE RECEIVED
10/26/99
FIELD DATA SUBMITTED BY
S.C.
MIX DATA SUBMITTED BY
TXI
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM
,. /
C-617 El OR C -1231 a
PLANT
N/A
DELIVER TICKET NO.
20319
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12 - )
(ASTM C -39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
98
LAB
11/01/99
7
85,407
28.27
3,020
99
LAB
11/22/99
28
103,336
28.27
3,660
100
LAB
1.1/22/99
28
102,533
28.27
3,630
101
LAB
HOLD
H
28.27
specifications 28 1
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
❑ Cylinders delivered to ALPHA
laboratory.
Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
10/25/99
(REVISED 12/8/99)
98881 -101
Respectfu
AL HA TESTING, IN
Geotechnical Engineering a ,Construction Materials Teshng ■ Environmental Engineering ■ Consufhng
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 700
Dallas, Texas 75229
972/620 -897 7 - 9721263 -4937 (Metro)
FAX 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
DATE OF ISSUE
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO
COPPELL, TEXAS
10/25/99
(REVISED 12/8/99)
98881 -102
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 42 +00
DATE PLACED
10/25/99
TIME
14:20
SLUMP (ASTM C -143)
2.25
AIR CONTENT (ASTM C -231 ❑ OR C -173 D►
4.5
AIR TEMPERATURE
76
CONCRETE TEMPERATURE
80
DATE RECEIVED
10/26/99
FIELD DATA SUBMITTED BY
S.C.
MIX DATA SUBMITTED BY
TXI
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ❑ OR C -1231 G
PLANT
N/A
DELIVER TICKET NO.
20343
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6 X 12 - )
(ASTM C -39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
102
LAB
11/01/99
7
87,599
28.27
3,100
103
LAB
11/22/99
28
100,386
28.27
3,550
104
LAB
11/22/99
28
101,518
28.27
3,590
105
LAB
HOLD
H
28.27
5peclflcations 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
REPORT OF CONCRETE
COMPRESSION TEST
[3 Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
��- or Contractor's representative.
12 Cylinders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
�/ laboratory.
L�J Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
0
z pe Submitted H S C.
Geotechnical Engineering ■ Construction Materials Tesffng ■ Environmental Engineering ■ Consulting
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE: 10/26/99
(REVISED 12/8/99)
OUR REPORT NO.: 98881 -103
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 37 +25
DATE PLACED
10/26/99
PLANT
N/A
TIME
9:37
DELIVER TICKET NO.
20367
SLUMP (ASTM C -143)
2
MIX PROPORTIONS (SSD)
80,626
AIR CONTENT (ASTM C -231 ❑ OR C -173 9 —
4.25
CEMENT
N/A
AIR TEMPERATURE
72
WATER
N/A
CONCRETE TEMPERATURE
74
FINE AGGREGATE
N/A
DATE RECEIVED
10/27/99
COARSE AGGREGATE
N/A
FIELD DATA SUBMITTED BY
S.C.
ADMIXTURE
N/A
MIX DATA SUBMITTED BY
TXI
specificatlons 28
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12 ")
(ASTM C-39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
106
LAB
11/02/99
7
80,626
28.27
2,850
107
LAB
11/23/99
28
107,250
28.27
3,790
108
LAB
11/23/99
28
105,442
28.27
3,730
109
LAB
HOLD
H
28.27
specificatlons 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
blinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractors representative.
�nders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
��,, laboratory.
LYCompression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
0
R ctfully Submitted
ALPHA ,I
Geotechnical Engineering ■ Corwh chop Materials Teshng a Environmental Engineering ■ Consu"
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE
OUR REPORT NO
10/26/99
(REVISED 12/8/99)
98881 -104
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 35 +00
DATE PLACED
10/26/99
PLANT
N/A
TIME
12:30
DELIVER TICKET NO.
20397
SLUMP (ASTM C -143)
2.5
MIX PROPORTIONS (SSD)
87,050
/
[I �
AIR CONTENT (ASTM C -231 OR C -173 �)
5
CEMENT
N/A
AIR TEMPERATURE
86
WATER
N/A
CONCRETE TEMPERATURE
88
FINE AGGREGATE
N/A
DATE RECEIVED
10/27/99
COARSE AGGREGATE
N/A
FIELD DATA SUBMITTED BY
S.C.
ADMIXTURE
N/A
MIX DATA SUBMITTED BY
TXI
s 28
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 LT
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6 X 12 ")
(ASTM C-39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
110
LAB
11/02/99
7
87,050
28.27
3,080
111
LAB
11/23/99
28
111,219
28.27
3,930
112
LAB
11/23/99
28
109,918
28.27
3,890
113
LAB
HOLD
H
28.27
s 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
I23 made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractors representative.
Cylinders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
laboratory.
Lfl Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
7
Res ully Submitted
T ING
Geotechnical Engineering ■ Construction Materials Testing ■ Environmental Engineering I Consulting
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620-8917 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
DATE OF ISSUE:
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO
COPPELL, TEXAS
10/27/99
(REVISED 12/8/99)
98881 -106
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 35 +00
DATE PLACED
10/27/99
PLANT
N/A
TIME
13:25
DELIVER TICKET NO.
18810
SLUMP (ASTM C -143)
2
MIX PROPORTIONS (SSD)
70,006
AIR CONTENT (ASTM C -231 ❑ OR C -173 Qr
4.5
CEMENT
N/A
AIR TEMPERATURE
83
WATER
N/A
CONCRETE TEMPERATURE
84
FINE AGGREGATE
N/A
DATE RECEIVED
10/28/99
COARSE AGGREGATE
N/A
FIELD DATA SUBMITTED BY
S.C.
ADMIXTURE
N/A
MIX DATA SUBMITTED BY
TXI
specifications 28
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 ❑ OR C -1231
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12 - )
(ASTM C39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
118
LAB
11/03/99
7
70,006
28.27
2,480
119
LAB
11/24/99
28
99,590
28.27
3,520
120
LAB
11/24/99
28
100,946
28.27
3,570
121
LAB
HOLD
H
28.27
specifications 28
1 3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractors representative.
Cylinders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
laboratory.
Er-compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
Z LP s ully Submitted
HA TESTIN C.
Geotechnical Engineering ■ Construction Materials Testing I Environmental Engineering ■ Consu"
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620 -8911 - 972/263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE
OUR REPORT NO
Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractors representative.
L;-'6ylinders picked up by ALPHA
laboratory.
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 22 +50
DATE PLACED
10/28/99
PLANT
N/A
TIME
10:15
DELIVER TICKET NO.
18742
SLUMP (ASTM C -143)
3
MIX PROPORTIONS (SSD)
95,418
AIR CONTENT (ASTM C -231 ❑ OR C -173 C3-
'4.5
CEMENT
N/A
AIR TEMPERATURE
72
WATER
N/A
CONCRETE TEMPERATURE
74
FINE AGGREGATE
N/A
DATE RECEIVED
10/29/99
COARSE AGGREGATE
N/A
FIELD DATA SUBMITTED BY
S.C.
ADMIXTURE
N/A
MIX DATA SUBMITTED BY
TXI
s 28
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM
C-617 ❑ OR C -1231
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6 X 12 ")
(ASTM C39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
122
LAB
11/04/99
7
95,418
28.27
3,380
123
LAB
11/25/99
28
113,733
28.27
4,020
124
LAB
11/25/99
28
115,860
28.27
4,100
125
LAB
HOLD
H
28.27
s 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
❑ Cylinders delivered to ALPHA
�,
/ laboratory.
13 Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
10/28/99
(REVISED 12/8/99)
98881 -107
R ctfully Submitte
ALP NG, INC.
Geotechnical Engineering ■ Construction Materials Testing ■ Environmental Engineering ■ Consulting
A
ALPHA TESTING, INC.
2209 Wisconsin St„ Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
DATE OF ISSUE:
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO
COPPELL, TEXAS
10/28/99
(REVISED 1218/99)
98881 -108
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 19 +50
DATE PLACED
10/28/99
TIME
13:25
SLUMP (ASTM C -143)
3
AIR CONTENT (ASTM C -231 ❑ OR C -173 2r
4.5
AIR TEMPERATURE
80
CONCRETE TEMPERATURE
84
DATE RECEIVED
10/29/99
FIELD DATA SUBMITTED BY
S.C.
MIX DATA SUBMITTED BY TXI —/
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 Ll
PLANT
N/A
DELIVER TICKET NO.
18761
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12 ")
(ASTM C-39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
126
LAB
11/04/99
7
94,984
28.27
3,360
127
LAB
11/25/99
28
114,869
28.27
4,060
128
LAB
11/25/99
28
116,509
28.27
4,120
129
LAB
HOLD
H
28.27
Specifications 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
REPORT OF CONCRETE
COMPRESSION TEST
a Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractor's representative.
❑Minders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
�
' laboratory.
LJ Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
U
Respectfull mitted
A TESTI , NC.
Geotechnical Engineering ■ Conshvction Materials Testing I Environmental Engineering ■ Consulting
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE:
OUR REPORT NO
10/29/99
(REVISED 12/8/99)
98881 -109
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 12 +50
DATE PLACED
10/29/99
TIME
10:15
SLUMP (ASTM C -143)
2.5
AIR CONTENT (ASTM C -231 ❑ OR C -173
4.5
AIR TEMPERATURE
73
CONCRETE TEMPERATURE
76
DATE RECEIVED
11
FIELD DATA SUBMITTED BY
S.C.
MIX DATA SUBMITTED BY
TXI
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 G�
PLANT
N/A
DELIVER TICKET NO.
18730
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6 X 12 - )
(ASTM C -39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
130
LAB
11/05/99
7
85,615
28.27
3,030
131
LAB
11/26/99
28
103,245
28.27
3,650
132
LAB
11/26/99
28
105,332
28.27
3,730
133
LAB
HOLD
H
28.27
I specifications 28
3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
ET-Cylinders made by ALPHA
representative.
❑ Cylinders made by Architects
or Contractors representative.
0--(5 �finders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
,/ laboratory.
E Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
Res fully Submitted
LPHA TES G, I
Geotechnical Engineering ■ Construction Matenals Testing ■ Environmental Engineering ■ Consutttng
A
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 700
Dallas, Texas 75229
9721620 -897 l - '9721263-4937 (Metro)
FAX: 9721406 -8023
TESTED FOR: CITY OF COPPELL
COPPELL, TEXAS
REPORT OF CONCRETE
COMPRESSION TEST
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02
COPPELL, TEXAS
DATE OF ISSUE
OUR REPORT NO.
10/29/99
(REVISED 12/8/99)
98881 -110
FIELD DATA
LOCATION OF CONCRETE PLACEMENT PAVING: SANDY LAKE ROAD, STATION 9 +00
DATE PLACED
10/29/99
TIME
13:00
SLUMP (ASTM C -143)
2
AIR CONTENT (ASTM C -231 ❑ OR C -173 Q�-'
5
AIR TEMPERATURE
77
CONCRETE TEMPERATURE
77
DATE RECEIVED
11/01/99
FIELD DATA SUBMITTED BY
S.C.
MIX DATA SUBMITTED BY
TXI
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231
PLANT
N/A
DELIVER TICKET NO.
18666
MIX PROPORTIONS (SSD)
AREA
CEMENT
N/A
WATER
N/A
FINE AGGREGATE
N/A
COARSE AGGREGATE
N/A
ADMIXTURE
N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER - SIZE 6 X 12 - )
(ASTM C-39)
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
134
LAB
11/05/99
7
80,010
28.27
2,830
135
LAB
11/26/99
28
107,671
28.27
3,810
136
LAB
11/26/99
28
109,335
28.27
3,870
137
LAB
HOLD
H
28.27
specificationS 28
1 3,500
REMARKS: CONCRETE POURED BY MACHINE AND BY MIXING TRUCK
Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
2--Cylinders or Contractor's representative.
picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
/ laboratory.
0 Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
Res p ly Submitted
ALPHA TESTING, I
Geotechnical Engineering ■ Consfruchon Materials Tesfing I Environmental Engineering ■ Consulhng