Loading...
ST9302-LR991117ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 9721620 -8911 - 9721263 -4937 (Metro) FAX: 9721406 -8023 REPORT OF CONCRETE COMPRESSION TEST TESTED FOR: CITY OF COPPELL DATE OF ISSUE: 11/17/99 COPPELL, TEXAS PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO.: 98881 -113 COPPELL, TEXAS FIELD DATA LOCATION OF CONCRETE PLACEMENT SIDEWALK: SANDY LAKE ROAD, 200' WEST OF CORNER OF HEARTZ STREET DATE PLACED 11/19/99 PLANT 29 TIME 14:45 DELIVER TICKET NO. 385049 SLUMP (ASTM C -143) 4 MIX PROPORTIONS (SSD) 75,082 AIR CONTENT (ASTM C -231 ❑ OR C -173 5.5 CEMENT N/A AIR TEMPERATURE 80 WATER NIA CONCRETE TEMPERATURE 86 FINE AGGREGATE N/A DATE RECEIVED 11/20199 COARSE AGGREGATE N/A FIELD DATA SUBMITTED BY S. M. ADMIXTURE N/A MIX DATA SUBMITTED BY PIONEER Specifications 28 SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231 COMPRESSION TEST RESULTS (NOMINAL CYLINDER SIZE 6 X 12 - ) (ASTM C LAB NO. TYPE CURING DATE TESTED AGE DAYS TOTAL LOAD AREA COMPRESSIVE STRENGTH, PSI 138 LAB 11/24/99 7 75,082 28.27 2,660 139 LAB 12/15/99 28 103,931 28.27 3,680 140 LAB 12/15/99 28 101,592 28.27 3,590 141 LAB HOLD H 28.27 Specifications 28 3,500 REMARKS: a Cylinders made by ALPHA representative. ❑ Cylinders made by Architect's or Contractors representative. I -nders picked up by ALPHA laboratory. ❑ Cylinders delivered to ALPHA ,,� laboratory. L�J Compression test results comply with applicable specifications. ❑ Compression test results do not comply with applicable specifications. N Reocttully S X /" ALPHA TESTING, I Geotechnical Engineering ■ Consbucfion Materials Teshng 1 Environmental Engineering ■ Consulting