ST9302-LR991117ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
9721620 -8911 - 9721263 -4937 (Metro)
FAX: 9721406 -8023
REPORT OF CONCRETE
COMPRESSION TEST
TESTED FOR: CITY OF COPPELL DATE OF ISSUE: 11/17/99
COPPELL, TEXAS
PROJECT: SANDY LAKE ROAD PROJECT NO. ST 93 -02 OUR REPORT NO.: 98881 -113
COPPELL, TEXAS
FIELD DATA
LOCATION OF CONCRETE PLACEMENT SIDEWALK: SANDY LAKE ROAD, 200' WEST OF CORNER OF
HEARTZ STREET
DATE PLACED
11/19/99
PLANT
29
TIME
14:45
DELIVER TICKET NO.
385049
SLUMP (ASTM C -143)
4
MIX PROPORTIONS (SSD)
75,082
AIR CONTENT (ASTM C -231 ❑
OR C -173 5.5
CEMENT
N/A
AIR TEMPERATURE
80
WATER
NIA
CONCRETE TEMPERATURE
86
FINE AGGREGATE
N/A
DATE RECEIVED
11/20199
COARSE AGGREGATE
N/A
FIELD DATA SUBMITTED BY
S. M.
ADMIXTURE
N/A
MIX DATA SUBMITTED BY
PIONEER
Specifications 28
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C -617 ❑ OR C -1231
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6 X 12 - )
(ASTM C
LAB
NO.
TYPE
CURING
DATE
TESTED
AGE
DAYS
TOTAL
LOAD
AREA
COMPRESSIVE
STRENGTH, PSI
138
LAB
11/24/99
7
75,082
28.27
2,660
139
LAB
12/15/99
28
103,931
28.27
3,680
140
LAB
12/15/99
28
101,592
28.27
3,590
141
LAB
HOLD
H
28.27
Specifications 28
3,500
REMARKS:
a Cylinders made by ALPHA
representative.
❑ Cylinders made by Architect's
or Contractors representative.
I -nders picked up by ALPHA
laboratory.
❑ Cylinders delivered to ALPHA
,,� laboratory.
L�J Compression test results comply with
applicable specifications.
❑ Compression test results do not comply
with applicable specifications.
N
Reocttully S
X /"
ALPHA TESTING, I
Geotechnical Engineering ■ Consbucfion Materials Teshng 1 Environmental Engineering ■ Consulting