ST9302-LR 990329
I~A TESTING. INC.
2209 Wisconsin St" Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
REPORT OF CONCRETE
COMPRESSION TEST
8
TESTED FOR:
CITY OF COPPELL DA TE OF ISSUE:
COPPELL, TEXAS
PROJECT:
SANDY LAKE ROAD PROJECT NO. ST 93-02 OUR REPORT NO.:
COPPELL, TEXAS
03/03/99
(REVISED 3129199)
98881-19
LOCATION OF CONCRETE PLACEMENT
FIELD DATA
SANDY LAKE ROAD DRAINAGE CHANNEL, STATION 3+50
DATE PLACED 03/03/99
TIME 15:30
SLUMP (ASTM C-143. _ ~ 5
AIR CONTENT (ASTM C-231 0 OR C-173 or 4
AIR TEMPERATURE 75
CONCRETE TEMPERATURE 80
DATE RECENED 03/04/99
FIELD DATA SUBMmED BY PECH
MIX DATA SUBMITTED BY N/A /"
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-8171a""" OR C"1231 0
PLANT N/A
DELNER TICKET NO. 169952
MIX PROPORTIONS (SSD)
CEMENT N/A
WATER N/A
FINE AGGREGATE N/A
COARSE AGGREGATE N/A
ADMIXTURE N/A
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6" X 12")
(ASTM C-39)
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
9 LAB 03/1 0/99 7 77,965 28.27 2,760
10 LAB 03/31/99 28 123.597 28.27 4,370
11 LAB 03/31/99 28 104,346 28.27 3,690
12 LAB HOLD H 28.27
Specifications 28 3,000
REMARKS: CHANNEL 3000 PSI PER STAN PHILLIPS CITY OF COPPELL
INSPECTOR.
~inders made by AlPHA
representative.
o Cylinders made by Architect's
or Contreclor's representative.
~inders picked up by ALPHA
laboratory.
o Cylinders delivered to ALPHA
~.
~esSioo test results comply with
applicable specifications.
o Compressioo test results do not comply
with applicable specifications.
o
Geotechnkx1l Engineering . Construction Materials Testing . Environmental Engineering. Consulting
. ~
I I
I
n
I
I
1
.~ S-r-C,31.)2-
REPORT OF CONCRETE
COMPRESSION TEST
~\A ~SnNG, IN:
2209 Wisconsin St., Suite 100
Dallas, Texas 75229
972/620-8911 - 972/263-4937 (Metro)
FAX: 972/406-8023
TESTED FOR:
CITY OF COPPELL DATE OF ISSUE:
COPPEll, TEXAS
PROJECT:
SANDY LAKE ROAD PROJECT NO. ST 93-02 OUR REPORT NO.:
COPPEll, TEXAS
03/10/99
(REVISED 3/29/99)
98881-18
LOCATION OF CONCRETE PLACEMENT
FIELD DATA
CONCRETE WALL AT STATION 3+00 OF SOUTH WALL
PLANT 3
DELIVER TICKET NO. 194567
MIX PROPORTIONS (SSD)
CEMENT N/A
WATER N/A
FINE AGGREGATE N/A
COARSE AGGREGATE N/A
ADMIXTURE N/A
DATE PLACED 03/10/99
TIME 3:10
SLUMP (ASTM C-143) / 3
AIR CONTENT (ASTM C-231 0 OR C-173 9r' 4
AIR TEMPERATURE 69
CONCRETE TEMPERATURE 82
DATE RECEIVED 03/11/99
FIELD DATA SUBMITTED BY D. H.
MIX DATA SUBMITTED BY PIONEER/
SPECIMENS CAPPED IN ACCORDANCE WITH ASTM C-617 [J/"ORC-1231 0
COMPRESSION TEST RESULTS
(NOMINAL CYLINDER SIZE 6R X 12R)
(ASTM C-39)
LAB TYPE DATE AGE TOTAL AREA COMPRESSIVE
NO. CURING TESTED DAYS LOAD STRENGTH, PSI
13 LAB 03/17/99 7 73,284 28.27 2,590
14 LAB 04/07/99 28 145,421 28.27 5,140
15 LAB 04/07/99 28 129,146 28.27 4,570
16 LAB HOLD H 28.27
Specifications 28 3,000 (
REMARKS: CHANNEL 3000 PS' PER STAN PH'LUPS C'TY OF COPPELL \~
INSPECTOR
~nders made by ALPHA
representative.
o Cylinders made by Architect's
or Contractor's representative.
~inders picked up by ALPHA
laboratory.
o Cylinders delivered to ALPHA
laboratory.
o Compression test results comply with
applicable specifications.
o Compression test results do not comply
with applicable specifications.
o
Respectfully Submitted
ALPHA TESTING, INC.
Geotechnical Engineering. Construction Materials Testing. Environmental Engineering . Consufffng
"!"TI'F
11
I I
l!
1
lIl!
I