Loading...
ST9302-LR000418REPORT OF FIELD A COMPACTION TESTS ALPHA TESTING, INC. 2209 Wisconsin St., Suite 100 Dallas, Texas 75229 �, 9721620 -8911 - 9721263 -4937 (Metro) k FAX: 9721406 -8023 TESTED FOR CITY OF COPPELL DATE 04/18/00 COPPELL, TEXAS �GGI' PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881 -11 PROJECT NO. ST 93 -02 �,Ct►� �� �� ` COPPELL, TEXAS TEST DATA: TEST NO. DATE ELEV. DEPTH SOIL ID NUMBER OPTIMUM MOISTURE % MAXIMUM LAB DRY DENSITY POE IN PLACE MOISTURE % IN PLACE DRY DENSITY PCF PERCENT COMPACTION COMMENT 326 04/18/00 FG -3.0 7 21.5 99.6 27.2 86 87 1 -BC 327 04/18/00 FG -2.0 7 21.5 99.6 26.0 88 89 1 -BC 328 04/18/00 FG -1.0 7 21.5 99.6 27.7 84 4 1 -BC TEST LOCATION: 326 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +46 327 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +42 328 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +38 CC: NONE 1. FILL A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS 2. NATURAL SUBGRADE B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS 3. LIME STABILIZED C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS 4. CEMENTTREATED D. RETEST Geotechnical Engineering I Construction Materials Testing 9 Environmental Engineering