ST9302-LR000418REPORT OF FIELD
A COMPACTION TESTS
ALPHA TESTING, INC.
2209 Wisconsin St., Suite 100
Dallas, Texas 75229 �,
9721620 -8911 - 9721263 -4937 (Metro) k
FAX: 9721406 -8023
TESTED FOR CITY OF COPPELL DATE 04/18/00
COPPELL, TEXAS �GGI'
PROJECT SANDY LAKE ROAD OUR REPORT NO. 98881 -11
PROJECT NO. ST 93 -02 �,Ct►� �� �� `
COPPELL, TEXAS
TEST DATA:
TEST
NO.
DATE
ELEV.
DEPTH
SOIL ID
NUMBER
OPTIMUM
MOISTURE
%
MAXIMUM LAB
DRY DENSITY
POE
IN PLACE
MOISTURE
%
IN PLACE
DRY DENSITY
PCF
PERCENT
COMPACTION
COMMENT
326
04/18/00
FG -3.0
7
21.5
99.6
27.2
86
87
1 -BC
327
04/18/00
FG -2.0
7
21.5
99.6
26.0
88
89
1 -BC
328
04/18/00
FG -1.0
7
21.5
99.6
27.7
84
4
1 -BC
TEST LOCATION:
326 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +46
327 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +42
328 18" SANITARY SEWER SOUTH SIDE SANDY LAKE ROAD AT STATION #32 +38
CC: NONE
1. FILL
A. IN PLACE PERCENT MOISTURE AND PERCENT COMPACTION COMPLY WITH SPECIFICATIONS
2. NATURAL SUBGRADE
B. PERCENT COMPACTION DOES NOT COMPLY WITH SPECIFICATIONS
3. LIME STABILIZED
C. PERCENT IN PLACE MOISTURE DOES NOT COMPLY WITH SPECIFICATIONS
4. CEMENTTREATED
D. RETEST
Geotechnical Engineering I Construction Materials Testing 9 Environmental Engineering