Loading...
Gateway BP(1.6)-LR061110FIELD DENSITY TESTING Report Number: 94061163.0144 Service Date: November 1, 2006 11~rracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: ProLogis Attn: Keith Porter 2310 LBJ Freeway Ste 200 Dallas TX 75234 Report Date: November 10, 2006 Project: Freeport Corporate Ctr. Bldg. 6 Freeport Pkwy & Gateway Coppell, TX Project No.: 94061163 Lab Test Data Proiect Requirements Material Information Optimum Max. Lab Water Dry Unit Water Minimum Dry Material Laboratory Content Weight Content Unit Weight No. Test Method Description and Classification (%) (pcf) (%) (%compaction) 1 611630001 ASTM D 698 Dark grayish brown & brown clay 25.4 92.8 >/_ +4 92-98 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elev. No. (inches) (%) (pcf) (% compaction) Leaveout Backfill 495 50' N of SE corner 2' BFG 1 6 29.8 85.8 92 496 50' N of SE corner 1' BFG 1 6 29.5 86.6 93 497 200' N of SE corner 2' BFG 1 6 30.1 85.9 93 498 200' N of SE corner 1' BFG 1 6 30.5 85.5 92 499 40' W of SE corner 2' BFG 1 6 25.2 * 92.4 100 500 40' W of SE corner 1' BFG 1 6 24.9 * 92.0 99 501 25' E of SW corner 2' BFG 1 6 29.4 87.0 94 502 25' E of SW corner 1' BFG 1 6 29.6 86.4 93 503 30' N of SW corner 3' BFG 1 6 26.5 * 90.9 98 504 30' N of SW corner 2' BFG 1 6 26.1 * 91.4 98 Datum: BFG =below final grade Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method: ASTM D-2922, ASTM D-3017 Terracon Rep: Francisco J. Morillo Field Results Reported To: Superintendent Report Distribution: (1) ProLogis (1) Meinhardt 8 Assoc Architects PLLC (1) City of Coppell TX (1) Jordan Construction Services Reviewed by: (1) City o(Coppell TX (1) Meinhardt b Assoc Architects PLLC Robert D. Ray, S. (1) Haynes Whaley Assoc Inc Senior Project er The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 D7-ACS/fiOT-FI101fe Key FIELD DENSITY TESTING Report Number: 94061163.0147 Service Date: November 2, 2006 l~erracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 630-1010 Client: Report Date: November 10, 2006 ProLogis Project: Freeport Corporate Ctr. Bldg. 6 Attn: Keith Porter Freeport Pkwy Sr Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Project No.: 94061163 Material Information Lab Test Data Proiect Requirements Optimum Max. Lab Water Dry Unit Water Minimum Dry Material Laboratory Content Weight Content Unit Weight No. Test Method Description and Classification (%) (pcf) (%) (% compaction) 1 611630001 ASTM D 698 Dark grayish brown & brown clay 25.4 92.8 >/_ +4 92-98 Field Test Data Probe Water Dry Unit Dry Unit Test Lift/ Mat. Depth Content Weight Weight No. Test Location Elev. No. (inches) {%) (pcf) (%compaction) Leaveout Backfill 505 RETEST OF TEST #499 - 40' W of SE 2' BFG 1 6 29.8 86.2 93 corner 506 RETEST OF TEST #500 - 40' W of SE 1' BFG 1 6 29.5 87.0 94 corner 507 RETEST OF TEST #503 - 30' N of SW 3' BFG 1 6 27.9 * 89.4 96 corner 508 RETEST OF TEST #504 - 30' N of SW 2' BFG 1 6 28.2 * 88.6 95 corner Datum: BFG =below final grade Comments: An asterisk (*) appears next to test results which do NOT meet the project specifications. Services - Perform in-place density and moisture content tests to determine degree of compaction and material moisture condition. Field Test Method: ASTM D-2922, ASTM D-3017 Terracon Rep: Francisco J. Morillo Field Results Reported To: Superintendent Report Distribution: (1) ProLogis (1) Meinhardt & Assoc Architects PLLC (1) City of Coppell TX (1) Jordan Construction Services Reviewed by: (1) City of Coppell TX (1) Meinhardt & Assoc Architects PLLC (1) Haynes Whaley Assoc Inc Robert D. Ra .E.T. Senior Proj Manager The tests were pertormed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 OT-ACS/R07-FWire Key