St Ann Catholic-LR061121REPORT OF REINFORCING STEEL OBSERVATION 1rerracon Consulting Enalneers & Scientists 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 !2141630 -1010 Date of Service: Client No.: Client: Services: 11/21/06 106235 St Ann Ca is Church 180 uel Blvd spell. TX 75019 Report No.: 94061334.0028 Project No.: 94061334 Project: St. Ann Catholic Parish New Addition 180 Samuel Blvd. Coppell, TX Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Drawings Utilized: Pavement Section Locations /Items Observed: Pavement for Staff Parking Lot Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT ITEMS OBSERVED CORRECT INCORRECT Placing Drawings Approved X Bar Length and Shape X Column Tie Spacing & Type Bar Size X Proper Bar Placement X Stirrup Spacing & Type Bar Grade X Properly Tied X Welded Splices Rebar Clean X Dowel Bars in Place X Mechanical Splices Trash & Debris Removed X Proper Bar Supports X Lapped Splices X Number of Bars X Proper Cover /Clearance X Discrepancies /Comments: Any discrepancies found were corrected prior to completion of observation. Field Results Report To: Technician: 1. Haynes Report Distribution: (1) St Ann Catholic Church (1) City of Coppell TX (1) City of Coppell TX 309acs (1) Page Southerland Page (1) TechniStructures (1) Pacheco Koch Consulting Engineers A. Bulent Ethem, P.G. Project Manager This report is exclusively for the use of the client indicated above and shall not be reproduced without written approval of Terracon. CONCRETE COMPRESSIVE STRENGTH TEST • 94061334 0004 Irerracon Report Number. 8901 Carpenter Frwy, Ste #100 Service Date: October 23, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: November 21, 2006 St Ann Catholic Church Project: St. Ann Ca Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No. 94061334 Material Information Specified Strength: 3600 psi c@ 28 Days Batch Time: 8:17am Supplier: Lattimore Truck No: 1050 Mix I.D. No.: 1701 Plant: 3 Ticket No: 3222083 Sample Information Date Cast: October 23, 2006 Time: 9:22am Sampled by: Ira S. Haynes Weather Conditions: Clear Accumulative Yards: 80 Placement Method: Direct Discharge Sample Locations: See attached sketch for Location #1 Placement Location: Pavement, Parking Lot Field Test Data Test Result Specification Test Metho Slump, inches: 5.00 3 -5 ASTM C143 Air Content, %: 4.3 3 -6 ASTM C231 Concrete Temperature, oF: 73 ASTM C1064 Ambient Temperature,oF: 64 ASTM C1064 Plastic Unit Weight, pcf: ASTM C138 Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area No. ID (inches) ( sq. inches Date Tested Test Load (days Ibs Strength (psi) 1 1 6.00 28.27 10/30/2006 7 95,190 3,370 1 2 6.00 28.27 11/20/2006 28 128,920 4,560 1 3 6.00 28.27 11/20/2006 28 128,420 4,540 Average (28 Days) 4,550 1 4 12/18/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical ma4ariale Page 1 of 2 01- C&R01 -F"o Key CONCRETE COMPRESSIVE STRENGTH TEST 61334 0004 1rerracon Report Number: 940 8901 Carpenter Frwy, Ste #100 Service Date: October 23, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: November 21, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 9406 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 11:06am Plant: 3 Supplier: Lattimore Truck No: 5022 Ticket No: 3222096 Mix I.D. No.: 1701 Water Added Onsite Before Test: 15Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Slump, inches: Air Content, %: Concrete Temperature, OF: Ambient Temperature, OF: Plastic Unit Weight, pcf: Result 5.25 4.3 83 77 Sample Information Date Cast: October 23, 2006 Time: 11:45am Sampled by: Ira S. Haynes Weather Conditions: Clear Accumulative Yards: 140/156 Placement Method: Direct Discharge Sample Locations: See attached sketch for Location #2 Placement Location: Pavement, Parking Lot, N Parking Specification 3 -5 3 -6 Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 2 3 6.00 28.27 11/20/2006 28 128,920 4,560 Average (28 Days) 4,580 2 4 12/18/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution: e (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client_ indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical matorialc Page 2 of 2 01- CS/R01 -FNtre Kay * = Field Test Results do not meet project specifications. Laboratory Test Data Age at Maximum Compressive Set Specimen Diameter Area Date Test Load Strength No. ID inches ( sq. inches Tested (days Ibs (psi) 2 1 6.00 28.27 10/30/2006 7 103,510 3,660 2 2 6.00 28.27 11/20/2006 28 129,930 4,590 2 3 6.00 28.27 11/20/2006 28 128,920 4,560 Average (28 Days) 4,580 2 4 12/18/2006 56 Comments: Not tested for plastic unit weight. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Ira S. Haynes Report Distribution: e (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Southerland Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client_ indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical matorialc Page 2 of 2 01- CS/R01 -FNtre Kay ^ .' Mo EiE 0. to WALK 70 m Lo Icc tu gi OHL 4 r- CA Ol zz qo 710�1 253.37'