Loading...
St Ann Catholic-LR061117Irerracon CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0016 8901 Carpenter Frwy, Ste #100 Service Date: November 9, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: Novemb 17, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 9:48 AM Plant: 6 Supplier: Lattimore Materials Co. Truck No: 1109 Ticket No: 6293732 Mix I.D. No.: 1701 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 0 Gallons Field Te Data Test Result Slump, inches: 6.50 Air Content, %: 8.0 Concrete Temperature, OF: 77 Ambient Temperature,OF: 73 Plastic Unit Weight, pcf: 134.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches ( sq. inches 1 1 6.00 28.27 1 2 4 Sample Information Date Cast: November 9, 2006 Time: 10:30 AM Sampled by: Jesus Rojas Weather Conditions: Cloudy, sunny Accumulative Yards: 40/200 Placement Method: Direct Discharge Sample Locations: Noted as Set 1 on sketch Placement Location: Paving, refer to attached sketch Specification Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested da s) Ibs (Psi 11/16/2006 7 71,500 2,530 12/07/2006 28 12/07/2006 28 01/04/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. 0t- PDRJR01- "F. N.Y Page 1 of 2 . CONCRETE COMPRESSIVE STRENGTH TEST Irerracon Report Number: 94061334.0016 8901 Carpenter Frwy, Ste #100 Service Date: November 9, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: November 17, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 11:14 AM Plant: 6 Supplier: Lattimore Materials Co. Truck No: 7057 Ticket No: 6293747 Mix I.D. No.: 1701 Water Added Onsite Before Test: OGallons Water Added Onsite After Test: 15 Gallons Field Test Data Test Result Slump, inches: 5.00 Air Content, %: 6.0 Concrete Temperature, OF: 81 Ambient Temperature,OF: 80 Plastic Unit Weight, pcf: 141.6 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 Sample Information Date Cast: November 9, 2006 Time: 11:50 AM Sampled by: Jesus Rojas Weather Conditions: Cloudy, sunny Accumulative Yards: 140/200 Placement Method: Direct Discharge Sample Locations: Noted as Set 2 on sketch Placement Location: Paving, refer to attached sketch Specification Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days Ibs (psi 11/16/2006 7 83,350 2,950 2 2 12/07/2006 28 2 3 12/07/2006 28 2 4 01/04/2007 56 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Jesus Rojas Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX A. Bulent Ethem, P.G. (1) Page Sou Page Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 2 °'- `°R'R °' �'°'° K., REPORT OF REINFORCING STEEL OBSERVATION Irerracan Consulting Engineers & Scientists 8901 Carpenter Frwy., Suite #100 Dallas, Texas 75247 f214) 630 -1010 Date of Service 11/17/06 Report No.: 94061334.0024 Client No Client: Services: 106235 Project No.: 94061334 St Ann Catholic Church Project: St. Ann Catholic Parish 180 Samuel Blvd New Addition Coppell, TX 75019 180 Samuel Blvd. Coppell, TX Observe placement of reinforcing for compliance with furnished drawings. PROJECT DATA Drawings Utilized: C4.1/Paving Notes, dated 8/10/06 Locations /Items Observed: Paving, E of St. Ann's Catholic Parish Test Method: Visual Observation REPORT OF OBSERVATION ITEMS OBSERVED Placing Drawings Approved CORRECT X INCORRECT ITEMS OBSERVED Bar Length and Shape CORRECT X INCORRECT ITEMS OBSERVED Column Tie Spacing & Type CORRECT INCORRECT Bar Size X Proper Bar Placement X Stirrup Spacing & Type X Properly Tied X Welded Splices Bar Grade X Dowel Bars in Place X Mechanical Splices Reber Clean X Proper Bar Supports X Lapped Splices X Trash &Debris Removed X Proper Cover /Clearance X Number of Bars Discrepancies/Comments: No discrepancies were noted at the time of this observation. Field Results Report To: Technician: Jose A. Martinez Report Distribution: (1) St Ann Catholic Church (1) City of Coppell TX (1) City of Coppell TX 309pdr (1) Page Southerland Page (1) Tech niStructures (1) Pacheco Koch Consulting Engineers A. Bulent Ethem, P.G. Project Manager This report is exclusively for the use of the client indicated above and shall not be reproduced without written approval of Terracon.