Loading...
Lauth Park-CS061130 DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Lauth Park Center, Lots 1 and 2, Block A, Minor Plat, to establish lot lines and various easements, to allow the development of a medical office on Lot 1 containing 6.67 acres of property, and the future development of Highway Commercial uses on Lot 2, containing 5.69 acres of property located at the northwest corner of SH 121 and N. Denton Tap Road, at the request of David G. Suarez, Lauth Property Group. STAFF REP.: Matt Steer PROJECT ID# MP-06-0066 DRC DATE: November 30, 2006 and December 7, 2006 CONTACT: Kenneth M. Griffin, P.E., Dir.of Engineering/Public Works 972/304-3686 COMMENT STATUS: PRELIMINARY FINAL REVISED  AFTER P&Z 1.Drainage easement should be shown on both Lots 1 and 2 for the proposed drainage systems and detention basins. 2.A property owner's Association should be formed to maintain the detention areas and any other common improvements. 3.A minimum 20' x 20' Utility Easement should be provided for the proposed double checks. If the double check coming off of Denton Tap Road remains in its current location, then a larger easement than 20' x 20' will be required. 4.The typical "floodplain note" should be provided on the plat. 5.You will need TxDOT approval for construction within the S.H. 121 right-of-way for your deceleration lane and also for the relocation of the existing inlets. 6.How is your brick screening wall proposed to go around the proposed culvert and headwall at the north side of Lot 1? Utility Plan 7. Please be advised that you cannot tie your 8" sanitary sewer line into the existing 27" sanitary sewer line, which is a City of Lewisville sewer line. The only existing sewer line that you could tie into is along the north edge of Lot 1 or you can extend a sewer line along the southern edge of Lots 1 and 2 to connect back to an existing City of Coppell sewer line in Denton Tap Road. Additional comments may be generated upon detailed engineering review. DEVELOPMENT REVIEW COMMITTEE ENGINEERING COMMENTS ITEM: Lauth Park Center, Lot 1 Block A, Site Plan, to allow the development of a three-story, 68,350-square-foot medical office on 6.67 acres of property located northwest of the corner of SH 121 and N. Denton Tap Road, at the request of David G. Suarez, Lauth Property Group. STAFF REP.: Matt Steer PROJECT ID# SPA-06-0065 DRC DATE: November 30, 2006 and December 7, 2006 CONTACT: Kenneth M. Griffin, P.E., Dir.of Engineering/Public Works 972/304-3686 COMMENT STATUS: PRELIMINARY FINAL REVISED  AFTER P&Z 1.The proposed sign should be removed from the existing 20 foot Utility Easement adjacent to the north side of S.H. 121. 2.Consideration should be given to extending the fire lane eastward through the parking area on Lot 1 and through Lot 2 to Denton Tap Rd. to provide for appropriate fire lane circulation when Lot 2 is developed in the future. Additional comments may be generated upon detailed engineering review.