Loading...
St Ann Catholic-LR061124CONCRETE COMPRESSIVE STRENGTH TEST Irerracon Report Number: 94061334.0019 8901 Carpenter Frwy, Ste #100 Service Date: November 14, 2006 Dallas, Texas 75247 (214) 630 -1010 Client: Report Date: November 24, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 7:10 AM Plant: 6 Supplier: Lattimore Materials Co Truck No: 976 Ticket No: 6294057 Mix I.D. No.: 1701 Water Added Onsite Before Test: 20Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 6.50 Air Content, %: 5.4 Concrete Temperature, oF: 70 Ambient Temperature,OF: 68 Plastic Unit Weight, pcf: 143.2 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( s q. iq nches 1 1 6.00 28.27 Sample Information Date Cast: November 14, 2006 Time: 7:45 AM Sampled by: Mario A. Garcia Weather Conditions: Accumulative Yards: 20/250 Placement Method: Direct Discharge Sample Locations: Set 1 on sketch Placement Location: Paving, N of new addition. E of existing church, refer to attached sketch Specification Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days (lbs) (psi) 11/21/2006 7 114,040 4,030 1 2 12/12/2006 28 1 3 12/12/2006 28 1 4 01/09/2007 56 Comments: Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 Of 3 oi- vowaoi -Fw,re Key CONCRETE COMPRESSIVE STRENGTH TEST Re ort Number• 94061334 0019 Irerracon 11 Service Date: November 14, 2006 Dall Carpenter Fn Ste #100 Dallas, Texas 75247 7 (214) 630 -1010 Client: Report Date: November 24, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Project No.: 94061334 Material Information Specified Strength: 3600 psi @ 28 Days Batch Time: 8:30 AM Plant: 6 Supplier: Lattimore Materials Co Truck No: 944 Ticket No: 6294069 Mix I.D. No.: 1701 Water Added Onsite Before Test: 5Gallons Water Added Onsite After Test: 5 Gallons Field Test Data Test Result Slump, inches: 6.50 Air Content, %: 6.3 Concrete Temperature, OF: 70 Ambient Temperature, OR 65 Plastic Unit Weight, pcf: 142.0 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 2 1 6.00 28.27 Sample Information Date Cast: November 14, 2006 Time: 9:15 AM Sampled by: Mario A. Garcia Weather Conditions: Sunny Accumulative Yards: 110/250 Placement Method: Direct Discharge Sample Locations: Set 2 on sketch Placement Location: Paving, N of new addition. E of existing church, refer to attached sketch Specification Test Metho ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days (lbs) (psi) 11/21/2006 7 127,210 4,500 2 2 12/12/2006 28 2 3 12/12/2006 28 2 4 01/09/20 56 Comments: Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 2 of 3 01-0DR 01- Fd—Key CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061334.0019 Service Date: November 14, 2006 Irerracon 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214) 6 30 -1010 Client: Report Date: November 24, 2006 St Ann Catholic Church Project: St. Ann Catholic Parish Attn: Jennifer Lindsey New Addition 180 Samuel Blvd 180 Samuel Blvd. Coppell TX 75019 Coppell, TX Plastic Unit Weight, pcf: Project No.: 94061334 Material Information Specified Strength: 3600 psi c@ 28 Days Batch Time: 10:55 AM Plant: 6 Supplier: Lattimore Materials Co Truck No: 7023 Ticket No: 6294096 Mix I.D. No.: 1701 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 6.50 Air Content, %: 8.8 Concrete Temperature, oF: 75 Ambient Temperature,OF: 73 Plastic Unit Weight, pcf: 139.2 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) ( sq. inches 3 1 6.00 28.27 Sample Information Date Cast: November 14, 2006 Time: 11:30 AM Sampled by: Mario A. Garcia Weather Conditions: Partly cloudy Accumulative Yards: 210/250 Placement Method: Direct Discharge Sample Locations: Set 3 on sketch Placement Location: Paving, N of new addition. E of existing church, refer to attached sketch Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days (lbs) (psi) 11/21/2006 7 119,390 4,220 3 2 12/12/2006 28 3 3 12/12/2006 28 3 4 01/09/2007 56 Comments: NOTE: Dustin with Frank Dale Construction was notified of high slump and air content in testing. Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Field Results Reported To: Dustin w /Frank Dale Constructi Terracon Rep: Mario A. Garcia Report Distribution: (1) St Ann Catholic Church (1) TechniStructures (1) City of Coppell TX (1) Pacheco Koch Consulting Engineers Reviewed by: (1) City of Coppell TX (1) Page Southerland Page A. Bulent Ethem, P.G. Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is Zclu e ly for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 3 of 3 01- PORIROi -F", Key ( ran' .9 f ' �1 Terracon Report No. 94061334.0019 Dated 11/14/06 m