Loading...
Gateway BP(1.6)-LR061129CONCRETE COMPRESSIVE STRENGTH TEST Report Number: 94061163.0166 l~~rr~con Service Date: November 21, 2006 8901 Carpenter Frwy, Ste #100 Dallas, Texas 75247 (214)630-1010 Client: Report Date: November 29, 2006 ProLogis Project: Freeport Corporate Ctr. Bldg. 6 Attn: Keith Porter Freeport Pkwy & Gateway 2310 LBJ Freeway Ste 200 Coppell, TX Dallas TX 75234 Project No.: 94061163 Material Information Specified Strength: 3500 psi ~ 28 Days Batch Time: 7:42 AM Plant: 27 Supplier: Southern Star Concrete Truck No: 1020 Ticket No: 1462162 Mix I.D. No.: 9339 Water Added Onsite Before Test: 0 Gallons Water Added Onsite After Test: 0 Gallons Field Test Data Test Result Slump, inches: 7.00 Air Content, %: 3,7 Concrete Temperature, oF: 60 Ambient Temperature,~F: 42 Plastic Unit Weight, pcf: 142.9 Laboratory Test Data Set Specimen Diameter Area No. ID (inches) (sq. inches) 1 1 6.00 28.27 Sample Information Date Cast: November 21, 2006 Time: 8:25 AM Sampled by: Michael W. Whyman Weather Conditions: Sunny, light winds Accumulative Yards: 50/60 Placement Method: Direct Discharge Sample Locations: P.6-Q Placement Location: Sidewalk, E side of building cLD E.5-Q Specification Test Method ASTM C143 ASTM C231 ASTM C1064 ASTM C1064 ASTM C138 Age at Maximum Compressive Date Test Load Strength Tested (days) (Ibs) (psi) 11/28/2006 7 82,480 2,920 1 2 6.00 28.27 11/28/2006 7 80,880 2,860 Average (7 Days) 2,890 1 3 12/19/2006 28 1 4 12/19/2006 28 Services - Obtain samples of fresh concrete at the placement locations, perform required field tests and cast compressive strength samples. Terracon Rep: Michael W. Whyman Report Distribution: (1) ProLogis (t) Meinhardt ~ Assoc Architects PLLC (1) City of Coppell TX {1) Jordan Construction Services Reviewed by: (1) City of Coppell TX (1) Meinhardt 8 Assoc Architects PLLC Robert D. Ra S (1) Haynes Whaley Assoc Inc Y. Senior Project Manager The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. Page 1 of 1 m.poa,au,-F~~~,a Key